Related Experiment Video
Updated: Jan 20, 2026

A Personalized 3D-Printed Model for Preoperative Evaluation in Thyroid Surgery
Published on: February 17, 2023
Monitoring and Evaluation of Thyroid Function Tests, Serum Electrolytes and Creatinine Levels Before and After 131I
Rubaida Mehmood1, Muhammed S Khan1, Sajid Hussain1
1Diagnostics Labs and Nuclear Medicine Department, Multan Institute of Nuclear Medicine and Radiotherapy (MINAR), PAEC, Multan, Pakistan.
Background:
Serum electrolytes, Creatinine, and thyroid profile play an important role in 131I treated patients of thyroid disorders.
Objectives:
To determine the effect of radioactive iodine (131I) on renal parameters, serum electrolytes and the correlation among TFT'S, creatinine, and chloride levels before and after I131 treatment in thyroid disorders.
Methods:
The study was performed on 55 patients of thyrotoxicosis with age ranging from 16-65 years (mean age= 41±14years and BMI=24.8±4.46). The significance of the differences between the results of 1st, 2nd, and 3rd-time serum analysis was assessed by paired Student's t-test. Association between parameters was assessed by Spearman correlation analysis.
Results:
40 patients were taking Carbimazole, and 15 were directly recommended for I131 therapy. Strongly significant variations were observed for TFT'S (T3=0.012, T4 =0.017, and TSH=0. 001) during the follow-up treatment. Before taking I131 (Serum analyzed at 1st time), there observed negative correlation of T3(r=-.46, p=0. 002) and TSH (r=-0.31, p=0.02) with creatinine, and positive correlation of TSH(r=0.29,p=0.02) with chloride. BMI was negatively correlated with potassium(r=-0.30, p=0.02). At the 2nd time (after stopping the Carbimazole), no correlation results were observed. Two months after oral administration of 131I, creatinine, and chloride level was significantly increased (p=0.000), (P=0. 03) respectively, but had no correlation with TFT'S.
Conclusion:
Our findings suggest that patients with goiter (diffused or toxic) have association of TFT'S and BMI with serum electrolytes and creatinine, 131I therapy is also associated with the increase in creatinine and chloride levels of patients leading to kidney problems.
Related Concept Videos
Serum Studies: Renal Function Tests
04:42A Personalized 3D-Printed Model for Preoperative Evaluation in Thyroid Surgery
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
05:21Computerized Adaptive Testing System of Functional Assessment of Stroke
09:45An In Vitro Protocol for Evaluating MicroRNA Levels, Functions, and Associated Target Genes in Tumor Cells
09:30Microbial Control and Monitoring Strategies for Cleanroom Environments and Cellular Therapies
