In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Noninvasive, in vivo rodent brain optical coherence tomography at 2.1 microns
Abstract:
In biological tissue, longer near-infrared wavelengths generally experience less scattering and more water absorption. Here we demonstrate an optical coherence tomography (OCT) system centered at 2.1 microns, whose bandwidth falls in the 2.2 micron water absorption optical window, for in vivo imaging of the rodent brain. We show in vivo that at 2.1 microns, the OCT signal is actually attenuated less in cranial bone than at 1.3 microns, and is also less susceptible to multiple scattering tails. We also show that the 2.2 micron window enables direct spectroscopic OCT assessment of tissue water content. We conclude that with further optimization, 2.2 micron OCT will have advantages in low-water-content tissue such as bone, as well as applications where extensive averaging is possible to compensate absorption losses.
Related Concept Videos
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
In Vivo Imaging of the Mouse Retina Using Optical Coherence Tomography
09:49Micron-scale Resolution Optical Tomography of Entire Mouse Brains with Confocal Light Sheet Microscopy
09:31In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
07:28Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging
08:17Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo