Related Experiment Video
Updated: Jan 20, 2026

08:21
Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
11.7K
Diagnosing plasmas with wideband THz pulses: errata
Optics Letters
|August 30, 2019
Summary
A new diagnostic method uses wide-band terahertz (THz) pulses to measure electron plasma density and temperature. This technique is valuable for characterizing plasma profiles in applications like laser-driven acceleration.
Area of Science:
- Plasma Physics
- Optics and Photonics
- THz Spectroscopy
Background:
- Accurate characterization of plasma parameters is crucial for advancing plasma-based technologies.
- Existing diagnostic methods may have limitations in spatial resolution or applicability to specific plasma regimes.
Purpose of the Study:
- To present an updated erratum for a previously published figure.
- To introduce a novel diagnostic method for determining electron plasma density and temperature.
- To describe the accompanying model and its utility.
Main Methods:
- Utilizing wide-band terahertz (THz) pulses for plasma diagnostics.
- Developing and describing a theoretical model to interpret THz-plasma interactions.
- Applying the method to characterize plasma density and temperature profiles along an axis.
Main Results:
- An updated figure (Fig. 3) is provided as part of this erratum.
- The presented diagnostic method effectively measures electron plasma density and temperature.
- The model aids in characterizing the plasma density and temperature profile.
Conclusions:
- The THz pulse-based diagnostic offers a valuable tool for plasma characterization.
- This method is particularly relevant for laser-produced plasma channels and plasma acceleration schemes.
- The updated erratum ensures accuracy in the presented diagnostic methodology.
Related Concept Videos
08:21Wideband Optical Detector of Ultrasound for Medical Imaging Applications
11.7K
Optical detection of ultrasound is impractical in many imaging scenarios because it often requires stable environmental conditions. We demonstrate an optical technique for ultrasound sensing in volatile environments with miniaturization and sensitivity levels appropriate for optoacoustic imaging in restrictive scenarios, e.g. intravascular...
11.7K
Diagnosing Acidosis and Alkalosis
1.1K
Diagnosing acid-base imbalances involves systematically analyzing arterial blood samples, focusing on three key measurements: pH, bicarbonate (HCO3−) concentration, and carbon dioxide partial pressure (PCO2). This analysis follows a four-step process that helps identify the imbalance's underlying cause and nature.
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
1.1K
Pulse
2.0K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.0K
Pulse
3.5K
The pulse is one of the most fundamental physiological indicators of the body's cardiovascular health. It is the rhythmic expansion and contraction of the arterial walls in response to the pressure generated by the heart's pumping action.
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
3.5K
07:37Basic Research in Plasma Medicine - A Throughput Approach from Liquids to Cells
13.3K
A high-throughput cold physical plasma treatment protocol of liquids and cells is shown. It involves setting up different feed gas compositions for plasma ignition, measuring the plasma's emission spectra, and the subsequent analysis of liquids and cellular activity after plasma...
13.3K
13:44Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
15.9K
This protocol outlines the simulation, fabrication and characterization of THz metamaterial absorbers. Such absorbers, when coupled with an appropriate sensor, have applications in THz imaging and...
15.9K