Related Experiment Video
Updated: Jan 20, 2026

Mimicking a Space Mission to Mars Using Hindlimb Unloading and Partial Weight Bearing in Rats
Published on: April 4, 2019
A novel device to measure static hindlimb weight-bearing forces in pronograde rodents
Morika D Williams1, Samantha L Sommer2, Rachel C Meyers3
1Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC, United States; Translational Research in Pain Program, North Carolina State University, Raleigh, NC, United States; Comparative Medicine Institute, North Carolina State University, Raleigh, NC, United States.
Background:
Joint pain is composed of both spontaneous and movement-induced pain. In animal models, static bodyweight distribution is a surrogate for spontaneous joint pain. However, there are no commercially-available instruments that measure static bodyweight distribution in normal, pronograde rodents.
New Method:
We designed a Static Horizontal Incapacitance Meter (SHIM) to measure bodyweight distribution in pronograde standing rodents. We assessed the device for feasibility, repeatability, and sensitivity to quantify hindlimb bodyweight distribution. Mice and rats with unilateral inflammatory pain induced by subcutaneous injections of capsaicin or Complete Freund's Adjuvant (CFA) into the plantar surface of the left hind paw were used to measure static weight-bearing. The ability to attenuate inflammatory pain-associated weight-bearing asymmetry was tested by administering a non-steroidal anti-inflammatory drug, meloxicam.
Results:
The SHIM's ability to detect significant reductions in limb loading on the injected hindlimb in mice and rats was validated using both acute and sub-chronic pain models. Treatment with meloxicam partially reversed CFA-induced effects.
Comparison With Existing Methods:
In contrast with assays that measure kinetic or static weight-bearing forces (e.g., walking, or standing at a 45 ° incline), the SHIM allows evaluation of weight-bearing in rodents that are standing at rest in their normal pronograde position.
Conclusions:
The SHIM successfully detected: (a) asymmetric weight-bearing in acute and sub-chronic pain models; and (b) the analgesic effects of meloxicam. This study provides a novel tool to objectively evaluate limb use dysfunction in rodents.
Related Concept Videos
05:54Mimicking a Space Mission to Mars Using Hindlimb Unloading and Partial Weight Bearing in Rats
05:07Early Weight-Bearing Rehabilitation Protocol After Anterior Cruciate Ligament Reconstruction
Pitot-static Tube: A Device to Measure Air Flow Speed
A Pitot-static tube is widely used for measuring unknown speeds in air flow, for example, it is used to measure airplane airspeed. By Bernoulli's principle, airspeed is directly related to variations in pressure. Therefore, the Pitot-static tube senses the stagnation pressure and static pressure. It is connected to a manometer or pressure transducer...
04:35Implantation of Optoelectronic Devices in the Rodent Spinal Cord
Static and Kinetic Frictional Force
However, if two systems are in contact and are stationary relative to one...
05:55Tension-Free Weight-Bearing Model of Steroid-Induced Osteonecrosis of Femoral Head in Rats