Large Field Alpha Irradiation Setup for Radiobiological Experiments

Stefan J Roobol1,2,3, Jasper J M Kouwenberg4, Antonia G Denkova5

  • 1Department of Molecular Genetics, Erasmus University Medical Center, Rotterdam, 3000 CA, The Netherlands.

Methods and Protocols
|August 31, 2019
PubMed

Related Concept Videos

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments06:08

Use of a Linear Accelerator for Conducting In Vitro Radiobiology Experiments

Clinical linear accelerators can be used to determine biologic effects of a wide range of dose rates on cancer cells. We discuss how to set up a linear accelerator for cell-based assays and assays for cancer stem-like cells grown as tumorspheres in suspension and cell lines grown as adherent...
7.9K
Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities06:51

Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

This document describes a new dosimetry protocol for cell irradiations using low energy X-ray equipment. Measurements are performed in conditions simulating real cell irradiation conditions as much as...
5.5K
Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments06:40

Automated Delivery of Microfabricated Targets for Intense Laser Irradiation Experiments

A protocol is presented for automated irradiation of thin gold foils with high intensity laser pulses. The protocol includes a step-by-step description of the micromachining target fabrication process and a detailed guide for how targets are brought to the laser's focus at a rate of 0.2...
4.7K
PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator10:48

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator

In the past, small animal irradiation was usually performed without the ability to target a well-delineated tumor volume. The goal was to mimic the treatment of human glioblastoma in rats. Using a small animal irradiation platform, we performed MRI-guided 3D conformal irradiation with PET-based sub-volume boosting in a preclinical...
10.0K
Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition06:20

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition

Radiation dosimetry provides a technique for enhancing the accuracy of preclinical experiments and ensuring that the radiation doses delivered are closely related to clinical parameters. This protocol describes steps to be taken at each phase during preclinical radiation experiments to ensure proper experimental...
7.7K
Practical Aspects of Sample Preparation and Setup of 1H R1ρ Relaxation Dispersion Experiments of RNA08:17

Practical Aspects of Sample Preparation and Setup of 1H R Relaxation Dispersion Experiments of RNA

We present a protocol to measure micro- to millisecond dynamics on 13C/15N-labeled and unlabeled RNA with 1H R1ρ relaxation dispersion nuclear magnetic resonance (NMR) spectroscopy. The focus of this protocol lies in high-purity sample preparation and setup of NMR...
5.2K