Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Tracing the Ferroptotic Signatures and Cell Death Dynamics in Medulloblastoma for Advanced Therapeutics
Published on: March 15, 2024
The Validation of Neogen Reveal® Q+ for DON
R Lucas Gray1, Alex Kostin1, Gabrielle Anderson1
1Neogen Corporation, 620 Lesher Pl, Lansing, MI 48912.
The Reveal Q+ for DON test accurately quantifies deoxynivalenol (DON) in grains. This validated method offers simple, rapid, and reliable mycotoxin determination for various commodities.
Area of Science:
- Agricultural Science
- Food Safety
- Analytical Chemistry
Background:
- The Reveal® Q+ for DON is an immunochromatographic assay designed for the quantitative determination of deoxynivalenol (DON) in various grain matrices.
- Deoxynivalenol (DON) is a significant mycotoxin that can contaminate staple crops, posing risks to animal and human health.
Purpose of the Study:
- To validate the performance of the Reveal Q+ for DON assay for the accurate quantification of deoxynivalenol.
- To assess the assay's efficacy across a wide range of commodities, including naturally contaminated and spiked samples.
Main Methods:
- Validation of the immunochromatographic test for deoxynivalenol (DON) determination.
- Inclusion of matrix testing, limit of detection (LOD), linearity, selectivity, robustness, and stability studies.
- Comparison of test results with reference values and independent laboratory testing for corroboration.
Main Results:
- The assay demonstrated reliable quantification of DON with high recovery rates (90-104%) and excellent linearity (R² = 0.999).
- Selectivity testing confirmed no cross-reactivity with other mycotoxins, and stability studies established an 18-month shelf life.
- The limit of quantification (LOQ) was determined to be 0.042 ppm in corn and 0.11 ppm in wheat.
Conclusions:
- The Reveal Q+ for DON test is a validated Performance Tested Method for deoxynivalenol determination in corn, wheat, and other grains.
- The assay offers advantages such as simple aqueous extraction, procedural ease, minimal equipment needs, and rapid results, making it suitable for routine analysis.
Related Concept Videos
Reliability and Validity
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Data Validation
Key parameters for method validation include:
04:01Revealing the Ferroptotic Phenotype of Medulloblastoma
05:37An R-Based Landscape Validation of a Competing Risk Model
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...