Background And Purpose:
4D-DSA allows time-resolved 3D imaging of the cerebral vasculature. The aim of our study was to evaluate this method in comparison with the current criterion standard 3D-DSA by qualitative and quantitative means using computational fluid dynamics.
Materials And Methods:
3D- and 4D-DSA datasets were acquired in patients with cerebral aneurysms. Computational fluid dynamics analysis was performed for all datasets. Using computational fluid dynamics, we compared 4D-DSA with 3D-DSA in terms of both aneurysmal geometry (quantitative: maximum diameter, ostium size [OZ1/2], volume) and hemodynamic parameters (qualitative: flow stability, flow complexity, inflow concentration; quantitative: average/maximum wall shear stress, impingement zone, low-stress zone, intra-aneurysmal pressure, and flow velocity). Qualitative parameters were descriptively analyzed. Correlation coefficients (r, P value) were calculated for quantitative parameters.
Results:
3D- and 4D-DSA datasets of 10 cerebral aneurysms in 10 patients were postprocessed. Evaluation of aneurysmal geometry with 4D-DSA (r maximum diameter = 0.98, P maximum diameter <.001; r OZ1/OZ2 = 0.98/0.86, P OZ1/OZ2 < .001/.002; r volume = 0.98, P volume <.001) correlated highly with 3D-DSA. Evaluation of qualitative hemodynamic parameters (flow stability, flow complexity, inflow concentration) did show complete accordance, and evaluation of quantitative hemodynamic parameters (r average/maximum wall shear stress diastole = 0.92/0.88, P average/maximum wall shear stress diastole < .001/.001; r average/maximum wall shear stress systole = 0.94/0.93, P average/maximum wall shear stress systole < .001/.001; r impingement zone = 0.96, P impingement zone < .001; r low-stress zone = 1.00, P low-stress zone = .01; r pressure diastole = 0.84, P pressure diastole = .002; r pressure systole = 0.9, P pressure systole < .001; r flow velocity diastole = 0.95, P flow velocity diastole < .001; r flow velocity systole = 0.93, P flow velocity systole < .001) did show nearly complete accordance between 4D- and 3D-DSA.
Conclusions:
Despite a different injection protocol, 4D-DSA is a reliable basis for computational fluid dynamics analysis of the intracranial vasculature and provides equivalent visualization of aneurysm geometry compared with 3D-DSA.
Related Concept Videos
Computational Fluid Dynamics Simulations of Blood Flow in a Cerebral Aneurysm
The objective of this video is to describe recent advancements of computational fluid dynamic (CFD) simulations based on patient- or animal-specific vasculature. Here, subject-based vessel segmentations were created, and, using a combination of open-source and commercial tools, a high-resolution numerical solution was determined within a flow...
Quantitative Strain Mapping of an Abdominal Aortic Aneurysm
1Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
2Mechanical Engineering & Materials Science, Washington University in St. Louis, St Louis, Missouri
The mechanical behavior of soft tissues, such as blood vessels, skin, tendons, and other organs, are strongly influenced by their composition of elastin and collagen, which provide elasticity and strength. The fiber...
06:37Analyzing Melts and Fluids from Ab Initio Molecular Dynamics Simulations with the UMD Package
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Magnetic Resonance Imaging of Cerebral Aneurysms Using MPRAGE
18:50Microsurgical Clip Obliteration of Middle Cerebral Aneurysm Using Intraoperative Flow Assessment