Related Experiment Video
Updated: Jan 20, 2026

Correlative Light- and Electron Microscopy Using Quantum Dot Nanoparticles
Published on: August 7, 2016
The NanoSuit method: a novel histological approach for examining paraffin sections in a nondestructive manner by
Hideya Kawasaki1, Toshiya Itoh2, Yasuharu Takaku3
1Institute for NanoSuit Research, Preeminent Medical Photonics Education & Research Center, Hamamatsu University School of Medicine, Hamamatsu, Japan. gloria@hama-med.ac.jp.
Abstract:
Histological examination using the light microscopy is currently the gold standard for life science research and diagnostics. However, magnified observations are limited because of the limitations intrinsic to light microscopy. Thus, a dual approach, known as correlative light and electron microscopy (CLEM), has emerged, although several technical challenges remain in terms of observing myriad stored paraffin sections. Previously, we developed the NanoSuit method, which enabled us to keep multicellular organisms alive/wet in the high vacuum of a scanning electron microscope by encasing the sample in a thin, vacuum-proof membrane. The approach uses the native extracellular substance (ECS) or an ECS-mimicking substance to polymerize a membrane by plasma or electron beam irradiation. Since the resulting NanoSuit is flexible and dense enough to prevent a living organism's bodily gas and liquids from evaporating (which we refer to as the "surface shield enhancer" (SSE) effect), it works like a miniature spacesuit with sufficient electron conductivity for an SEM observation. Here, we apply the NanoSuit method to CLEM analysis of paraffin sections. Accordingly, the NanoSuit method permits the study of paraffin sections using CLEM at low and high magnification, with the following features: (i) the integrity of the glass slide is maintained, (ii) three-dimensional microstructures of tissue and pathogens are visualized, (iii) nuclei and 3,3'-diaminobenzidine-stained areas are distinct because of gold chloride usage, (iv) immunohistochemical staining is quantitative, and (v) contained elements can be analyzed. Removal of the SSE solution after observation is a further advantage, as this allows slides to be restained and stored. Thus, the NanoSuit method represents a novel approach that will advance the field of histology.
More Related Videos
Related Concept Videos
11:16Correlative Light- and Electron Microscopy Using Quantum Dot Nanoparticles
08:47Epon Post Embedding Correlative Light and Electron Microscopy
11:53Ultrastructural Localization of Endogenous LC3 by On-Section Correlative Light-Electron Microscopy
10:00Low-Cost Cryo-Light Microscopy Stage Fabrication for Correlated Light/Electron Microscopy
Histological Sample Preparation for Light Microscopy
09:21Mitochondria and Endoplasmic Reticulum Imaging by Correlative Light and Volume Electron Microscopy