Related Experiment Video
Updated: Jan 20, 2026

Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
Evaluation of raw-data-based and calculated electron density for contrast media with a dual-energy CT technique
Daisuke Kawahara1,2, Shuichi Ozawa3,4, Kazushi Yokomachi1
1Radiation Therapy Section, Division of Clinical Support, Hiroshima University Hospital, Hiroshima, 734-8551, Japan.
Objectives:
The aim of the current study is to evaluate the accuracy and the precision of raw-data-based relative electron density (REDraw) and the calibration-based RED (REDcal) at a range of low-RED to high-RED for tissue-equivalent phantom materials by comparing them with reference RED (REDref) and to present the difference of REDraw and REDcal for the contrast medium using dual-energy CT (DECT).
Methods:
The REDraw images were reconstructed by raw-data-based decomposition using DECT. For evaluation of the accuracy of the REDraw, REDref was calculated for the tissue-equivalent phantom materials based on their specified density and elemental composition. The REDcal images were calculated using three models: Lung-Bone model, Lung-Ti model and Lung-Ti (SEMAR) model which used single-energy metal artifact reduction (SEMAR). The difference between REDraw and REDcal was calculated.
Results:
In the titanium rod core, the deviations of REDraw and REDcal (Lung-Bone model, Lung-Ti model and Lung-Ti model with SEMAR) from REDref were 0.45%, 50.8%, 15.4% and 15.0%, respectively. The largest differences between REDraw and REDcal (Lung-Bone model, Lung-Ti model and Lung-Ti model with SEMAR) in the contrast medium phantom were 8.2%, -23.7%, and 28.7%, respectively. However, the differences between REDraw and REDcal values were within 10% at 20 mg/ml. The standard deviation of the REDraw was significantly smaller than the REDcal with three models in the titanium and the materials that had low CT numbers.
Conclusion:
The REDcal values could be affected by beam hardening artifacts and the REDcal was less accurate than REDraw for high-Z materials as titanium.
Advances In Knowledge:
The raw-data-based reconstruction method could reduce the beam hardening artifact compared with image-based reconstruction and increase the accuracy for the RED estimation in high-Z materials, such as titanium and iodinated contrast medium.
Related Concept Videos
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Calculating Standard Free Energy Changes
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
12:08From Voxels to Knowledge: A Practical Guide to the Segmentation of Complex Electron Microscopy 3D-Data
10:25Dual-color Correlative Light and Electron Microscopy for the Visualization of Interactions between Mitochondria and Lysosomes
04:11Exosome Isolation: A Density-based Ultracentrifugation Technique Using Sucrose Cushion to Separate Exosomes from Conditioned Media of Cultured Cells
