Contamination of hybrid hernia meshes compared to bioresorbable Phasix™ Mesh in a rabbit subcutaneous implant
Spencer P Lake1, Nathaniel F N Stoikes2, Amit Badhwar3
1Department of Mechanical Engineering & Materials Science, Washington University in St. Louis, St. Louis, MO, USA.
Background:
Hybrid hernia meshes combine biological tissue-derived extracellular matrix with permanent or resorbable synthetic. The objective of this study was to evaluate hybrid meshes (Gore® Synecor, Zenapro™, Ovitex™ 1S Reinforced Bioscaffold Permanent, and Ovitex™ 1S Reinforced Bioscaffold Resorbable) compared to non-hybrid, bioresorbable synthetic mesh (Phasix™ Mesh) in a rabbit bacterial inoculation model.
Materials And Methods:
Subcutaneous pockets were bilaterally created in male, New Zealand White rabbits (n = 25). Circular meshes (3.8 cm diameter) were implanted and inoculated with 1 × 106 colony forming units (CFU) of clinically-isolated methicillin-resistant Staphylococcus aureus (MRSA). A given animal received a single mesh type. Seven days post-inoculation, animals were euthanized and white material and microbial colonization were assessed by abscess scoring and CFU quantification, respectively. Non-parametric Kruskal-Wallis with Dunn's post-hoc tests compared results for different meshes.
Results:
Phasix™ Mesh and Synecor exhibited significantly lower abscess scores than Zenapro™, Ovitex™ 1S Permanent, and Ovitex™ 1S Resorbable (p < 0.05). All pocket swabs for Zenapro™ and Ovitex™ meshes were positive for MRSA (100%), with 20% of Synecor and 0% Phasix™ Mesh. Microbial colonization was significantly lower for Phasix™ Mesh (0 CFU) relative to Zenapro™ (6.73 × 107 CFU (median)), Ovitex™ 1S Permanent (7.87 × 107 CFU) and Ovitex™ 1S Resorbable (1.45 × 108 CFU), and for Synecor (0 CFU) relative to both Ovitex™ meshes. Phasix™ Mesh was the only device with no detectable abscess or microbial colonization.
Conclusion:
Phasix™ Mesh demonstrated no detectable abscess or microbial colonization at 7-days post-implantation and inoculation, in contrast with four hybrid meshes, which all demonstrated colonization in a rabbit bacterial inoculation model.
Related Concept Videos
05:15Application of a New Mesh Fixation Method in Laparoscopic Incisional Hernia Repair
10:52Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
10:32Transvaginal Mesh Insertion in the Ovine Model
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
09:58Syringe-injectable Mesh Electronics for Stable Chronic Rodent Electrophysiology
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...