Related Experiment Video
Updated: Jan 20, 2026

Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
Published on: June 16, 2022
Use of flexible cystoscopy at time of artificial urinary sphincter placement
M Francesca Monn1, Brian M Orr, Matthew J Mellon
1Department of Urology, Indiana University School of Medicine, Indianapolis, Indiana, USA.
Introduction:
Artificial urinary sphincters (AUS) are used to treat significant urinary incontinence. Flexible cystoscopy at the time of AUS placement provides relevant intraoperative feedback including confirmation that the AUS is functioning, visualization of coaptation, and evaluation for urethral injury. Current guidelines for placement of an AUS do not include flexible cystoscopy. The objective was to evaluate whether flexible cystoscopy at time of AUS placement changed cuff size at the time of surgery.
Materials And Methods:
A retrospective cohort study was performed to evaluate all patients undergoing AUS placement by a single surgeon between March 2013 and March 2017. The primary endpoint of the study was change in cuff size based on cystoscopy.
Results:
A total of 109 AUS were placed in 96 patients. In five (4.6%) cases flexible cystoscopy identified a lack of coaptation of the urethra despite appropriate sizing which resulted in down-sizing of the cuff. Five patients were identified as having a bladder neck contracture that was previously unrecognized as clinic cystoscopy was performed by the referring urologist and was reportedly normal. Three patients developed postoperative infections, two of these patients had a history of multiple AUS placement and revisions and the third patient had a history of cystectomy and neobladder.
Conclusions:
Flexible cystoscopy at time of AUS placement changed the cuff size in nearly 5% of cases. Flexible cystoscopy at time of AUS placement provides valuable feedback and should be recommended for low volume prosthetic surgeons.
Related Concept Videos
03:25Transcorporal Artificial Urinary Sphincter Cuff Placement in a Case Requiring Revision for Urethral Atrophy
06:31Probe-based Confocal Laser Endomicroscopy of the Urinary Tract: The Technique
05:25Ultrasonography of the Adult Male Urinary Tract for Urinary Functional Testing
Arterial Line Placement
When monitoring patients, it is important to obtain values that are accurate and reliable. Blood pressure monitoring is one of the essential vital signs, and for a majority of patients, measuring it utilizing non-invasive techniques provides accurate values. However, there are situations in which the blood pressure requires more exact, specific, and reliable measurements....
10:07Cystometric and External Urethral Sphincter Measurements in Awake Rats with Implanted Catheter and Electrodes Allowing for Repeated Measurements
07:40A Flexible Chamber for Time-Lapse Live-Cell Imaging with Stimulated Raman Scattering Microscopy