Related Experiment Video
Updated: Jan 20, 2026

A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Stabilization of a Type B1.1 Injury in a Morbidly Obese Patient Using an Internal Fixator in a Minimally Invasive
Tobias Fritz1, Benedikt J Braun1, Nils T Veith1
1Department of Trauma, Hand and Reconstrutive Surgery, Saarland University Hospital, Homburg, Germany.
Case:
In this case report, we present a novel stabilization technique of the pubic symphysis using an internal spinal fixator in a 78-year-old morbidly obese woman having a pelvic disruption type B1.1 (AO classification). We treated the disruption using an internal fixator to reduce the extent of the incision and soft-tissue damage.
Conclusions:
The use of an internal fixator, known from percutaneous spinal fixation, for the stabilization of the pubic symphysis in cases of disruption ("open book" injuries) may be an alternative to the standard plate fixation as a novel minimally invasive stabilization technique.
Related Concept Videos
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
04:13Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
07:17Establishing a Mouse Contusion Spinal Cord Injury Model Based on a Minimally Invasive Technique
04:50A Minimally Invasive, Fast Spinal Cord Lateral Hemisection Technique for Modeling Open Spinal Cord Injuries in Rats
05:10Multidisciplinary Approach to Obesity Management: A Case Report
04:09Minimal Invasive Resection of Large Retrosternal Thyroid Goiter