Related Experiment Video
Updated: Jan 20, 2026

Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
Published on: October 28, 2020
Are there normal values of phase analysis parameters for left ventricular dyssynchrony in patients with no structural
Erito Marques de Souza Filho1, Claudio Tinoco Mesquita2, Ronaldo Altenburg Gismondi3
1Erito Marques de Souza-Filho Federal Fluminense University (UFF) and Federal Rural University of Rio de Janeiro (UFRRJ).
Background:
ECG-gated single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy combined with phase analysis allows for the assessment of left ventricular dyssynchrony. However, there are several software programs available thereby introducing variability in outcome and normal values. The aim of this systematic review was to evaluate the variability between different programs as currently available in literature with a focus on normal values.
Methods:
A systematic review was performed using the Embase, LILACS and Medline databases looking for articles reporting on normal values of the most used phase analysis parameters. The search resulted in 110 articles from Medline, 349 from Embase and one from LILACS. After exclusion of duplicate articles, 370 documents remained. Of these only 13 were deemed eligible for the systematic review.
Results:
Phase SD and bandwidth are the main parameters used in dyssynchrony analysis. Most articles reviewed here used the Emory Cardiac ToolBox (ECTb) to determine the phase analysis parameters values, which varied greatly among the four software tested. The bandwidth and phase SD calculated by the Quantitative Gated SPECT (QGS) tends to be smaller than that calculated by the ECTb. In relation to the bandwidth, ECTb and cardioREPO (cREPO) have higher values than the other software programs. The value of entropy obtained from 4DM is lower than those obtained from QGS and cREPO.
Conclusion:
We found that normal values of phase analysis can vary among software programs and can be different even when the same software is used.
Related Concept Videos
06:34Evaluation of Left Ventricular Structure and Function using 3D Echocardiography
07:55Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice
12:09Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
08:21Point-of-Care Ultrasound: A Review of Ultrasound Parameters for Predicting Difficult Airways
09:05Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation