Related Experiment Video
Updated: Jan 20, 2026

A Simple and Rapid Protocol for Measuring Neutral Lipids in Algal Cells Using Fluorescence
Published on: May 30, 2014
An evaluation of measurement techniques for algal-derived organic nitrogen
1AOM Lab, School of Chemical Engineering, The University of New South Wales, Sydney, Australia.
Abstract:
Algal-derived organic matter (AOM) from algal blooms in water supply systems contains dissolved organic nitrogen (DON) and dissolved organic carbon (DOC) among other constituents. The DON and DOC are disinfection by-product (DBP) precursor compounds, and must be well characterised to facilitate effective removal, thus minimising DBP formation during disinfection. While DOC character has been studied extensively, DON analysis suffers from inaccuracies due to sample pre-treatment and instrument sensitivities. A liquid chromatography method that combines size exclusion chromatography with highly sensitive organic carbon and nitrogen detectors (LC-OCND) has been widely adopted for DOC analysis; however, its potential for application for DON charactersation has been suggested as a viable alternative to existing DON characterisation techniquesnot been assessed despite its potential. Hence, the aim was to compare the effectiveness of conventional total dissolved N-dissolved inorganic N (TN-DIN), and LC-OCND methods for analysing DON in AOM. A suite of N-containing model compounds representative of DON and AOM extracted from Chlorella vulgaris CS-42/7 and Microcystis aeruginosa CS-555/1 were used to evaluate the techniques. The DON of both model compounds and AOM was first analysed using the conventional method and, then, via LC-OCND. It was observed that LC-OCND had a better precision for DON when TN contained more DIN. LC-OCND provided direct quantitative measurements for bulk and fractionated DON and DIN, with little interference caused by DIN. Additionally, LC-OCND provided information on MW distribution and protein content of the AOM. For example, LC-OCND results showed that M. aeruginosa AOM contained more HMW material than C. vulgaris AOM. However, as LC-OCND uses UV oxidation, it could not completely oxidise complex aromatic structures, and thus had a lower recovery for HMW model compounds and algal DON in comparison to the conventional method that used high temperature catalytic oxidation. Overall, it is advised that a combination of LC-OCND and TN analysis be used to provide a more detailed characterisation of N-containing AOM and other similar HMW aquatic NOM samples.
Related Concept Videos
10:56A Simple and Rapid Protocol for Measuring Neutral Lipids in Algal Cells Using Fluorescence
The Nitrogen Cycle
05:40Comparison of Scale in a Photosynthetic Reactor System for Algal Remediation of Wastewater
Measurement: Derived Units
08:58High-Throughput Measurement and Classification of Organic P in Environmental Samples
08:18A Small-Scale Setup for Algal Toxicity Testing of Nanomaterials and Other Difficult Substances

