Magnetic Resonance Imaging and Freehand 3-D Ultrasound Provide Similar Estimates of Free Achilles Tendon Shape and
Daniel Devaprakash1, David G Lloyd1, Rod S Barrett1
1School of Allied Health Sciences, Griffith University, Queensland, Australia; Gold Coast Orthopaedic Research Engineering and Education Alliance (GCORE), Menzies Health Institute Queensland, Griffith University, Queensland, Australia.
Abstract:
The purpose of this study was to assess the similarity of free Achilles tendon shape and 3-D geometry between magnetic resonance imaging (MRI) and freehand 3-D ultrasound (3-DUS) imaging methods. Fourteen elite/sub-elite middle-distance runners participated in the study. MRI and 3-DUS scans of the Achilles tendon were acquired on two separate imaging sessions, and all 3-D reconstructions were performed using identical methods. Shape similarity of free Achilles tendon reconstructed from MRI and 3-DUS data was assessed using Jaccard index, Hausdorff distance and root mean square error (RMSE). The Jaccard index, Hausdorff distance and RMSE values were 0.76 ± 0.05, 2.70 ± 0.70 and 0.61 ± 0.10 mm, respectively. The level of agreement between MRI and 3-DUS for free Achilles tendon volume, length and average cross-sectional area (CSA) was assessed using Bland-Altman analysis. Compared to MRI, freehand 3-DUS overestimated volume, length and average CSA by 30.6 ± 15.8 mm3 (1.1% ± 0.6%), 0.3 ± 0.7 mm (0.6% ± 1.9%) and 0.3 ± 1.42 mm2 (0.4% ± 2.0%), respectively. The upper and lower limits of agreement between MRI and 3-DUS for volume, length and average CSA were -0.4 to 61.7 mm3 (-0.2% to 2.3%), -1.0 to 1.5 mm (-3.2% to 4.5%) and -2.5 to 3.1 mm2 (-3.5% to 4.3%), respectively. There were no significant differences between imaging methods in CSA along the length of the tendon. In conclusion, MRI and freehand 3-DUS may be considered equivalent methods for estimating shape and 3-D geometry of the free Achilles tendon. These findings, together with the practical benefits of being able to assess 3-D Achilles tendon shape and geometry in a laboratory environment and under isometric loading, make 3-DUS an attractive alternative to MRI for assessing 3-D free Achilles tendon macro-structure in future studies.
Related Concept Videos
08:11Ultrasound Tissue Characterization of Human Achilles Tendon by Stability Quantification of Echo Patterns
04:31A Platelet-Rich Plasma Injection into the Sectioned Achilles Tendon of a Rat
Cardiac Magnetic Resonance Imaging
In this video, high field, small-bore magnetic resonance imaging (MRI) with physiological monitoring is demonstrated to acquire gated cine loops of the murine cardiovascular system. This procedure provides a basis for assessing left-ventricular function, visualizing vascular networks, and quantifying motion of organs due to respiration. Comparable small animal...
09:59A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia
06:20Contrast-Enhanced Subharmonic Aided Pressure Estimation (SHAPE) Using Ultrasound Imaging with a Focus on Identifying Portal Hypertension
09:14Cardiac Magnetic Resonance Imaging at 7 Tesla