Related Experiment Video
Updated: Jan 20, 2026

In Vivo Electrophysiological Measurement of the Rat Ulnar Nerve with Axonal Excitability Testing
Published on: February 6, 2018
Measurement of axonal excitability: Consensus guidelines
Matthew C Kiernan1, Hugh Bostock2, Susanna B Park1
1Brain and Mind Centre, University of Sydney and Institute of Clinical Neurosciences, Royal Prince Alfred Hospital, Sydney 2006, Australia.
Abstract:
Measurement of axonal excitability provides an in vivo indication of the properties of the nerve membrane and of the ion channels expressed on these axons. Axonal excitability techniques have been utilised to investigate the pathophysiological mechanisms underlying neurological diseases. This document presents guidelines derived for such studies, based on a consensus of international experts, and highlights the potential difficulties when interpreting abnormalities in diseased axons. The present manuscript provides a state-of-the-art review of the findings of axonal excitability studies and their interpretation, in addition to suggesting guidelines for the optimal performance of excitability studies.
Related Concept Videos
04:56In Vivo Electrophysiological Measurement of the Rat Ulnar Nerve with Axonal Excitability Testing
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Using TMS to Measure Motor Excitability During Action Observation
Transcranial Magnetic Stimulation (TMS) is a non-invasive brain stimulation technique that involves passing current through an insulated coil placed against the scalp. A brief magnetic field is created by current in the coil, and because of the physical process of induction, this leads to a current in the nearby neural tissue. Depending on the duration, frequency, and magnitude of these magnetic...
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
09:31Measurement of Tension Release During Laser Induced Axon Lesion to Evaluate Axonal Adhesion to the Substrate at Piconewton and Millisecond Resolution
Guidelines in Case of a Laboratory Emergency
The most common laboratory emergencies include chemical spills, fire or explosion, electric shock, and personnel injuries. Most laboratory accidents occur due to poor planning or lack of attention. Therefore, it's always better to prevent accidents (being proactive) than having to take any actions during an emergency (being reactive). For example, always wear proper personal protective equipment (PPE) in the...