Related Experiment Video
Updated: Jan 20, 2026

Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Published on: February 14, 2017
Optimal experimental design for joint reflection-transmission ultrasound breast imaging: From ray- to wave-based
Naiara Korta Martiartu1, Christian Boehm1, Vaclav Hapla1
1Department of Earth Sciences, Eidgenössische Technische Hochschule Zürich, Zürich CH-8092, Switzerland.
Abstract:
Ultrasound computed tomography (USCT) is an emerging modality to image the acoustic properties of the breast tissue for cancer diagnosis. With the need of improving the diagnostic accuracy of USCT, while maintaining the cost low, recent research is mainly focused on improving (1) the reconstruction methods and (2) the acquisition systems. D-optimal sequential experimental design (D-SOED) offers a method to integrate these aspects into a common systematic framework. The transducer configuration is optimized to minimize the uncertainties in the estimated model parameters, and to reduce the time to solution by identifying redundancies in the data. This work presents a formulation to jointly optimize the experiment for transmission and reflection data and, in particular, to estimate the speed of sound and reflectivity of the tissue using either ray-based or wave-based imaging methods. Uncertainties in the parameters can be quantified by extracting properties of the posterior covariance operator, which is analytically computed by linearizing the forward problem with respect to the prior knowledge about parameters. D-SOED is first introduced by an illustrative toy example, and then applied to real data. This shows that the time to solution can be substantially reduced, without altering the final image, by selecting the most informative measurements.
More Related Videos
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
07:13Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
Related Concept Videos
08:07Ultrasound-based Pulse Wave Velocity Evaluation in Mice
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Reflection of Waves
07:13Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
10:53A Novel Application of Musculoskeletal Ultrasound Imaging
12:23Multi-modal Imaging of Angiogenesis in a Nude Rat Model of Breast Cancer Bone Metastasis Using Magnetic Resonance Imaging, Volumetric Computed Tomography and Ultrasound