A simple torque magnetometer for magnetic moment measurement of large samples: Application to permanent magnets and

S Brialmont1, J F Fagnard1, P Vanderbemden1

  • 1SUPRATECS and Department of Electrical Engineering and Computer Science (B28), University of Liège, Sart-Tilman, B-4000, Belgium.

Related Concept Videos

Magnetic Tweezers for the Measurement of Twist and Torque11:41

Magnetic Tweezers for the Measurement of Twist and Torque

Magnetic tweezers, a powerful single-molecule manipulation technique, can be adapted for the direct measurements of the twist (using a configuration called freely-orbiting magnetic tweezers) and torque (using a configuration termed magnetic torque tweezers) in biological macromolecules. Guidelines for performing such measurements are given, including applications to the study of DNA and associated nucleo-protein...
23.8K
Magnetic Moment of an Electron01:23

Magnetic Moment of an Electron

Electrons revolving around a nucleus are analogous to a circular current carrying loop. This current produces a magnetic dipole moment proportional to the electron's orbital angular momentum. Since the orbital angular momentum is quantized in terms of the reduced Planck's constant, the dipole moment is quantized in the Bohr Magneton. The value of the Bohr magneton is 9.27 x 10-24 Am2. Electrons also have an intrinsic spin angular momentum, and the associated spin magnetic moment is...
2.8K
Torque On A Current Loop In A Magnetic Field01:13

Torque On A Current Loop In A Magnetic Field

The most common application of magnetic force on current-carrying wires is in electric motors. These consist of loops of wire, which are placed between the magnets with a magnetic field. When current flows through the loops, the magnetic field applies torque, which causes the shaft to rotate, thus converting electrical energy to mechanical energy.
Consider a rectangular current-carrying loop containing N turns of wire, placed in a uniform magnetic field. The net force on a current-carrying loop...
5.8K
A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia09:59

A Magnetic Resonance Imaging Protocol for Stroke Onset Time Estimation in Permanent Cerebral Ischemia

A protocol for stroke onset time estimation in a rat model of stroke exploiting quantitative magnetic resonance imaging (qMRI) parameters is described. The procedure exploits diffusion MRI for delineation of the acute stroke lesion and quantitative T1 and T2 (qT1 and qT2) relaxation times for timing of stroke.
14.6K
Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT08:57

Measuring the Influence of Magnetic Vestibular Stimulation on Nystagmus, Self-Motion Perception, and Cognitive Performance in a 7T MRT

In this article, we describe the experimental setup, material, and procedures to assess reflexive eye movements, self-motion perception, and cognitive tasks under magnetic vestibular stimulation, as well as the anatomical orientation of the vestibular organs, in a 7 Tesla Magnetic resonance tomography (7T-MRT)...
2.4K
Simple Methods for the Preparation of Non-noble Metal Bulk-electrodes for Electrocatalytic Applications09:18

Simple Methods for the Preparation of Non-noble Metal Bulk-electrodes for Electrocatalytic Applications

A facile preparation method of electrodes using the bulk material Fe4.5Ni4.5S8 is presented. This method provides an alternative technique to conventional electrode fabrication and describes prerequisites for unconventional electrode materials including a straightforward electrocatalytic testing...
11.9K