Automated Analysis of C. elegans Fluorescence Images using SegElegans
Published on: October 10, 2025
Automated stitching of microscope images of fluorescence in cells with minimal overlap
Ji-Hyun Seo1, Sejung Yang2, Mi-Sun Kang1
1Department of Computer Science and Engineering, College of Engineering, Ewha Womans University, Seoul 03760, Republic of Korea.
Abstract:
The morphology of tumor cells is highly related to their phenotype and activity. To verify the drug response of a brain tumor patient, fluorescence microscope images of drug-treated patient-derived cells in each well are analyzed. Due to the limitation of the field of view (FOV), a large number of small FOVs are acquired to compose one complete microscope well. Here, we propose an automated method for accurately stitching tile-scanned fluorescence microscope images, even with noise and a narrow overlapping region between adjacent fields. The proposed method is based on intensity-based normalized cross-correlation (NCC) and a triangular method-based threshold. The proposed method's quantitative accuracy and the sensitivity of the input was compared to other existing stitching tools, MIST and FijiIS, setting manually stitched images as the ground truth. The test images were 20 samples of 3 × 3 grid images in three versions of the fluorescence channel. The distance between the location of each field and number of cells was determined for different input field overlap ranges (1%, 3%, 5%, and 10%), while the actual value was about 1.15%. The proposed method had a distance error of 1.5 pixels at an input overlap of 1%, showing the lowest minimum error at all channels. Regarding the difference in cell numbers, although the number of overlapping cells was always small because of the narrow overlapping range, the proposed method was able to generate the resultant image with the smallest difference. In addition, to confirm the size limitation of the proposed algorithm, the accuracy of stitching images of grid structures 3 × 3, 5 × 5, 10 × 10-20 × 20 was tested, showing consistent results. In conclusion, quantitative evaluation of the performance of the method proved its improved accuracy compared to other current state-of-art techniques, and it showed robust performance even with noise and a narrow overlapping region between adjacent fields.
Related Concept Videos
06:27Automated Analysis of C. elegans Fluorescence Images using SegElegans
15:10From Fast Fluorescence Imaging to Molecular Diffusion Law on Live Cell Membranes in a Commercial Microscope
11:01Automated Imaging and Analysis for the Quantification of Fluorescently Labeled Macropinosomes
07:06Semi-automated Imaging of Tissue-specific Fluorescence in Zebrafish Embryos
08:32Conducting Multiple Imaging Modes with One Fluorescence Microscope
Deep-Tissue Imaging of a Zebrafish Brain Using a Three-Photon Fluorescence Microscope