Performing optimal transcatheter aortic valve implantation: The need for tailored use of transcatheter valves
Quentin Fischer1, Marina Urena2, Claire Bouleti2
1Department of Cardiology, Bichat-Claude-Bernard Hospital, AP-HP, 75018 Paris, France; University Paris Diderot, 75013 Paris, France.
Background:
Despite the worldwide development of transcatheter aortic valve implantation (TAVI) over the last decade, strategies that take patient characteristics into account to guide the choice of transcatheter heart valve have not been evaluated.
Aim:
To evaluate the immediate results of TAVI using a tailored choice of balloon-expandable or self-expanding transcatheter heart valve, according to each patient's clinical and anatomical characteristics.
Methods:
This single-centre observational study included all patients treated with TAVI from 2012 to 2017. The 30-day results were reported according to Valve Academic Research Consortium-2 criteria. A total of 502 patients were included (mean age, 81±9 years; 52% men; mean EuroSCORE II, 7.0±6.5%). Three main variables guided the choice of transcatheter heart valve: the anatomy of the iliofemoral arteries and of the aortic root, and the general condition of the patient.
Results:
A SAPIEN™ balloon-expandable transcatheter heart valve was used in 275 patients (55%) and a CoreValve™ self-expanding transcatheter heart valve in 227 patients (45%). The approach was transfemoral in 427 patients (85%), and only 29 patients (6%) required transthoracic access. At 30-day follow-up, the rates of adverse events were as follows: mortality, 3.2%; stroke, 3.0%; major bleeding, 5.9%; and major vascular complications, 6.0%. Rates of complications at 30 days were similar in the SAPIEN™ and CoreValve™ groups, except for a higher rate of pacemaker implantation in the latter group (29.5% vs. 14.5%; P<0.001).
Conclusion:
The choice of balloon-expandable or self-expanding transcatheter heart valve tailored to the patient's clinical and anatomical characteristics allows for maximal use of the transfemoral approach, and is associated with low 30-day rates of major complications and mortality.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
07:46Automatic Surgery in Transcatheter Aortic Valve Replacement Using Augmented Reality