Preparation of a Reference Material for the Determination of Hexavalent Chromium in Tap Water
Tetsuo Inui1, Hamana Shirota1, Shoji Sakao1
1Analytical Chemistry Group, Chemical Engineering Department, Kanagawa Institute of Industrial Science and Technology.
Abstract:
We developed a reference material (RM) for the determination of hexavalent chromium (Cr(VI)) in tap water. The tap water RM was prepared by adding a Cr(VI) standard solution to the raw material without acidification, i.e., under the original pH conditions of 7.6, because the decrease in the concentration of Cr(VI) was observed when the tap water had been adjusted to pH 1 with HNO3. The prepared tap-water RM (2 L) was packed in 10 fluororesin (PFA) bottles with an inside plug (200 mL each). Each PFA bottle (Cr(VI)-containing tap water) was sealed in a reclosable poly bag and then stored at 5°C in a refrigerator. The tap water RM had a Cr(VI) concentration of 51 μg L-1. The concentration of Cr(VI) was determined by diphenylcarbazide absorptiometry using a 100-mm quartz cell. The detection limit of Cr(VI) in the sample solution corresponding to three-times the standard deviation (n = 5) of blank values was 0.51 μg L-1. The homogeneity of Cr(VI) in the tap water RM was evaluated by an analysis of the variance after the Cochran test. There was no significant difference between the within-bottle and between-bottle variances of the analytical results, indicating that the tap water RM was sufficiently homogeneous. The stability of Cr(VI) in the tap water RM was investigated by monitoring the Cr(VI) concentration over a period of 6 months. The slope of the regression line of the Cr(VI) concentration versus the storage time did not significantly differ from zero, indicating that the tap water RM was stable for 6 months. The concentrations (50 - 51 μg L-1) of Cr(VI) in the tap water RM were in good agreement with the total chromium concentrations (50 - 51 μg L-1) obtained by atomic absorption spectrometry.
Related Concept Videos
12:30Development and Validation of Chromium Getters for Solid Oxide Fuel Cell Power Systems
06:57Determining Viral Disinfection Efficacy of Hot Water Laundering
Assay for Cell Death: Chromium Release Assay of Cytotoxic Ability
1 Microbiology, Immunology, and Cancer Biology Graduate Program, University of Minnesota, Minneapolis, MN 55455
2 Center for Immunology, University of Minnesota, Minneapolis, MN 55455
3 Department of Urology, University of Minnesota, Minneapolis, MN 55455
4 Masonic Cancer Center, University of Minnesota, Minneapolis, MN 55455
One of the main functions of the cells of the immune system is to remove target cells...
04:35Preparation of Free-Surface Hyperbolic Water Vortices
05:52Resource Recycling of Red Soil to Synthesize Fe2O3/FAU-type Zeolite Composite Material for Heavy Metal Removal
08:09Use of an Eight-arm Radial Water Maze to Assess Working and Reference Memory Following Neonatal Brain Injury