A nicotinamide adenine dinucleotide (NADH)-coupled ATPase assay has been adapted to semihigh throughput screening of small molecule myosin inhibitors. This kinetic assay is run in a 384-well microplate format with total reaction volumes of only 20 µL per well. The platform should be applicable to virtually any ADP producing...
10.3K
High-throughput Antiviral Assays to Screen for Inhibitors of Zika Virus Replication10:16

High-throughput Antiviral Assays to Screen for Inhibitors of Zika Virus Replication

In this work, we describe the protocols used in replicon-based and viral enzyme-based assays to screen for inhibitors of Zika virus replication in a high-throughput screening...
4.2K
A Fluorescence-based Lymphocyte Assay Suitable for High-throughput Screening of Small Molecules08:43

A Fluorescence-based Lymphocyte Assay Suitable for High-throughput Screening of Small Molecules

We present in the current study a novel fluorescence-based assay using lymphocytes derived from a transgenic mouse. This assay is suitable for high-throughput screening (HTS) of small molecules endowed with the capacity of either inhibiting or promoting lymphocyte activation.
10.9K
A "Dual-Addition" Calcium Fluorescence Assay for the High-Throughput Screening of Recombinant G Protein-Coupled Receptors08:46

A "Dual-Addition" Calcium Fluorescence Assay for the High-Throughput Screening of Recombinant G Protein-Coupled Receptors

In this work, a high-throughput, intracellular calcium fluorescence assay for 384-well plates to screen small molecule libraries on recombinant G protein-coupled receptors (GPCRs) is described. The target, the kinin receptor from the cattle fever tick, Rhipicephalus microplus, is expressed in CHO-K1 cells. This assay identifies agonists and antagonists using the same cells in one "dual-addition"...
2.7K
High-throughput Screening for Chemical Modulators of Post-transcriptionally Regulated Genes09:44

High-throughput Screening for Chemical Modulators of Post-transcriptionally Regulated Genes

Here we describe a cell-based reporter gene assay as a valuable tool to screen chemical libraries for compounds modulating post-transcriptional control mechanisms exerted through 3’...
9.9K
High-throughput Screening for Small-molecule Modulators of Inward Rectifier Potassium Channels10:07

High-throughput Screening for Small-molecule Modulators of Inward Rectifier Potassium Channels

Methods for developing and validating a quantitative fluorescence assay for measuring the activity of inward rectifier potassium (Kir) channels for high-throughput compound screening is...