Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph

Shelby E White1, Cassandra K Conway1, Gabrielle L Clark1

  • 1Department of Biomedical Engineering, Tulane University.

Related Concept Videos

Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph09:59

Biaxial Basal Tone and Passive Testing of the Murine Reproductive System Using a Pressure Myograph

This protocol utilized a commercially available pressure myograph system to perform pressure myograph testing on the murine vagina and cervix. Utilizing media with and without calcium, the contributions of the smooth muscle cells (SMC) basal tone and passive extracellular matrix (ECM) were isolated for the organs under estimated physiological...
9.9K
A Novel Biaxial Testing Apparatus for the Determination of Forming Limit under Hot Stamping Conditions07:40

A Novel Biaxial Testing Apparatus for the Determination of Forming Limit under Hot Stamping Conditions

This protocol proposes a novel biaxial testing system used on a resistance heating uniaxial tensile test machine in order to determine the forming limit diagram (FLD) of sheet metals under hot stamping...
8.0K
Assessment of Vascular Tone Responsiveness using Isolated Mesenteric Arteries with a Focus on Modulation by Perivascular Adipose Tissues08:41

Assessment of Vascular Tone Responsiveness using Isolated Mesenteric Arteries with a Focus on Modulation by Perivascular Adipose Tissues

The protocol describes the use of wire myography to evaluate the transmural isometric tension of mesenteric arteries isolated from mice, with special consideration of the modulation by factors released from endothelial cells and perivascular adipose...
10.3K
Cardiac Loading using Passive Left Atrial Pressurization and Passive Afterload for Graft Assessment08:49

Cardiac Loading using Passive Left Atrial Pressurization and Passive Afterload for Graft Assessment

The protocol describes a porcine ex vivo heart perfusion system in which direct loading of the left ventricle may serve as an assessment technique for graft health while simultaneously providing a holistic evaluation of graft function. A discussion of the system design and possible assessment metrics is also...
1.3K
Biaxial Mechanical Characterizations of Atrioventricular Heart Valves11:00

Biaxial Mechanical Characterizations of Atrioventricular Heart Valves

This protocol involves characterizations of atrioventricular valve leaflets with force-controlled, displacement-controlled, and stress-relaxation biaxial mechanical testing procedures. Results acquired with this protocol can be used for constitutive model development to simulate the mechanical behavior of functioning valves under a finite element simulation...
14.8K
Design of a Biaxial Mechanical Loading Bioreactor for Tissue Engineering08:04

Design of a Biaxial Mechanical Loading Bioreactor for Tissue Engineering

We designed a novel mechanical loading bioreactor that can apply uniaxial or biaxial mechanical strain to a cartilage biocomposite prior to transplantation into an articular cartilage...
15.0K