Accuracy of Radiomics-Based Feature Analysis on Multiparametric Magnetic Resonance Images for Noninvasive Meningioma

Kai Roman Laukamp1, Georgy Shakirin2, Bettina Baeßler3

  • 1Institute for Diagnostic and Interventional Radiology, University Hospital Cologne, Cologne, Germany; Department of Radiology, University Hospitals Cleveland Medical Center, Cleveland, Ohio, USA; Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.

World Neurosurgery
|September 3, 2019
PubMed
Abstract

Related Concept Videos

Interslice Magnetization Transfer Ratio Imaging for Meningioma Detection01:26

Interslice Magnetization Transfer Ratio Imaging for Meningioma Detection

Begin with a patient with meningioma, or a brain tumor, positioned in an MRI scanner for non-invasive brain imaging.Adjust the scanner to obtain structural images of individual slices of the brain.Enhance the contrast to improve tissue differentiation.Use interslice magnetization transfer ratio imaging on brain slices using radiofrequency pulses slightly offset from the MRI signal.The pulses deliver energy to the proton pool in macromolecules and bound water molecules.This energy transfers to...
178
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

We describe how to obtain parametric and vector maps of the diffusion tensor of the breast using magnetic resonance imaging. The protocol and final output following imaging processing are tailored for tracking breast architectural features and detecting breast malignancy.
23.1K
fMRI: Functional Magnetic Resonance Imaging09:15

fMRI: Functional Magnetic Resonance Imaging

Functional magnetic resonance imaging (fMRI) is a non-invasive neuroimaging technique used to investigate human brain function and cognition in both healthy individuals and populations with abnormal brain states. Functional MRI utilizes a magnetic resonance signal to detect changes in blood flow that are coupled to neuronal activation when a specific task is performed. This is possible because hemoglobin within the blood has different magnetic properties depending on whether or not it is bound...
59.5K
Guidelines and Experience Using Imaging Biomarker Explorer (IBEX) for Radiomics10:17

Guidelines and Experience Using Imaging Biomarker Explorer (IBEX) for Radiomics

We describe IBEX, an open-source tool designed for medical imaging radiomics studies, and how to use this tool. In addition, some published works that have used IBEX for uncertainty analysis and model building are...
13.6K
Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking07:21

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking

An accurate and practical method to measure parameters like strain in myocardial tissue is of great clinical value, since it has been shown, that strain is a more sensitive and earlier marker for contractile dysfunction than the frequently used parameter EF.
14.8K
Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse12:24

Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse

This study demonstrates the successful establishment of magnetic resonance microscopy imaging as a non-invasive tool to assess the cardiac abnormalities in mice affected with autoimmune myocarditis. The data indicate that the technique can be used to monitor the disease-progression in live...