Related Experiment Video
Updated: Jan 20, 2026

Generation of Two-color Antigen Microarrays for the Simultaneous Detection of IgG and IgM Autoantibodies
Published on: September 15, 2016
Label-free electrochemical impedimetric immunosensor for sensitive detection of IgM rheumatoid factor in human serum
Somasekhar R Chinnadayyala1, Jinsoo Park2, Muhammad A Abbasi1
1Department of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do, 13120, South Korea.
Abstract:
The authors report a label-free and direct detection of rheumatoid factor- Immunoglobulin M (IgM-RF) based on an impedimetric-interdigitated wave type microelectrode array (IDWμE). IDWμE was functionalized with a self-assembled monolayer (SAM) of thioctic acid for antigen immobilization. The SAM functionalized IDWμE were characterized by atomic force microscopy, Energy Dispersive X-Ray Spectroscopy, and X-ray photoelectron spectroscopy. The covalent immobilization of IgG-Fc onto the SAM modified electrode arrays was characterized morphologically via AFM and electrochemically via cyclic voltammetry and electrochemical impedance spectroscopy. Impedimetric measurements in the presence of redox probe (Potassium ferrocyanide and potassium ferricyanide) showed a significant change in both the impedance spectrum and charge transfer resistance upon IgM-RF binding. Impedance measurements were target specific and linear with an increase in IgM-RF concentrations between 1 and 200 IU mL-1 in redox probe and human serum, respectively. The sensor showed detection limits of 0.6 IU mL-1 in the presence of redox probe and 0.22 IU mL-1 in the human serum. The biosensor exhibited good reproducibility (relative standard deviation (RSD), 4.96%) and repeatability (RSD, 2.31%) with an acceptable selectivity towards IgM-RF detection. The sensor also showed a good stability for 3 weeks at 4 °C in 1X PBS. Therefore, the sensitive and stable immunosensor exhibiting IDWμE features can be integrated with a miniaturized potentiostat to develop a sensing system that detects IgM-RF for point-of-care applications.
Related Concept Videos
10:16Generation of Two-color Antigen Microarrays for the Simultaneous Detection of IgG and IgM Autoantibodies
Electrochemical Biosensing
09:30Bacterial Detection & Identification Using Electrochemical Sensors
14:53A Microfluidic-based Electrochemical Biochip for Label-free DNA Hybridization Analysis
17:16Development of an Electrochemical DNA Biosensor to Detect a Foodborne Pathogen
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...