Related Experiment Video
Updated: Jan 20, 2026

Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
Published on: March 26, 2018
Minimally Invasive Sutureless Aortic Valve Replacement is Associated With Improved Outcomes in Patients With Left
Giovanni Concistrè1, Giacomo Bianchi1, Francesca Chiaramonti1
1Department of Adult Cardiac Surgery, G. Pasquinucci Heart Hospital, Fondazione CNR-G. Monasterio, Massa, Italy.
Objective:
Patients with severe aortic stenosis and reduced left ventricular ejection fraction (LVEF) have a poor prognosis compared with patients with preserved LVEF. To evaluate the impact of sutureless Perceval (LivaNova, Italy) aortic bioprosthesis on LVEF and clinical outcomes in patients with baseline left ventricular (LV) dysfunction who underwent isolated aortic valve replacement (AVR).
Methods:
Between March 2011 and August 2017, 803 patients underwent AVR with Perceval bioprosthesis implantation. Fifty-two isolated AVR had preoperative LVEF ≤45%. Mean age of these patients was 77 ± 6 years, 24 patients were female (46%), and mean EuroSCORE II was 9.4% ± 4.8%. Perceval bioprosthesis was implanted in 9 REDO operations. In 43 patients (83%), AVR was performed in minimally invasive surgery with an upper ministernotomy (n = 13) or right anterior minithoracotomy (n = 30).
Results:
One patient died in hospital. Cardiopulmonary bypass and aortic cross-clamp times were 85.5 ± 26 minutes and 55.5 ± 19 minutes, respectively. At mean follow-up of 33 ± 20 months (range: 1 to 75 months), survival was 90%, freedom from reoperation was 100%, and mean transvalvular pressure gradient was 11 ± 5 mmHg. LVEF improved from 37% ± 7% preoperatively to 43% ± 8% at discharge (P < 0.01) and further increased to 47% ± 9% at follow-up (P = 0.06), LV mass decreased from 149.8 ± 16.9 g/m2 preoperatively to 115.3 ± 11.6 g/m2 at follow-up (P < 0.001), and moderate paravalvular leakage occurred in 1 patient without hemolysis not requiring any treatment.
Conclusions:
AVR with sutureless aortic bioprosthesis implantation in patients with preoperative LV dysfunction demonstrated a significant immediate and early improvement in LVEF.
More Related Videos
Related Concept Videos
08:50Technique and Patient Selection Criteria of Right Anterior Mini-Thoracotomy for Minimal Access Aortic Valve Replacement
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
08:34Technique of Minimally Invasive Transverse Aortic Constriction in Mice for Induction of Left Ventricular Hypertrophy
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
06:51A Minimally Invasive Model of Aortic Stenosis in Swine
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs

