The initial U.S. experience with the Tempo active fixation temporary pacing lead in structural heart interventions
Tamim M Nazif1,2, Shmuel Chen2, Pablo Codner1
1Columbia University Irving Medical Center, New York, New York.
The Tempo lead offers safe and effective temporary cardiac pacing for structural heart procedures. It ensures stable pacing and allows patient mobilization, demonstrating good lead performance post-procedure.
Area of Science:
- Cardiology
- Medical Devices
- Interventional Procedures
Background:
- Temporary cardiac pacing is crucial for structural heart procedures.
- Existing temporary pacing leads have seen limited innovation.
- The Tempo lead features a soft tip and active fixation for improved safety and stability.
Purpose of the Study:
- To evaluate the safety and efficacy of the Tempo Temporary Pacing Lead in initial U.S. clinical use.
- To assess the performance of the Tempo lead during and after structural heart interventions.
Main Methods:
- Retrospective analysis of 269 consecutive structural heart procedures using the Tempo lead.
- Evaluation of device safety, including absence of perforation, effusion, or arrhythmia.
- Assessment of pacing efficacy, lead stability, and post-procedure outcomes.
Main Results:
- Successful pacing achieved in 98.1% of patients.
- No significant perforations, effusions, or device-related arrhythmias occurred.
- The lead enabled patient mobilization in 84.1% of cases without dislodgement.
Conclusions:
- The Tempo lead is a safe and effective option for temporary cardiac pacing in structural heart procedures.
- It provides reliable peri- and post-procedural pacing.
- The lead facilitates patient mobility while maintaining pacing stability.
More Related Videos
Related Concept Videos
07:49A Pacing-Controlled Procedure for the Assessment of Heart Rate-Dependent Diastolic Functions in Murine Heart Failure Models
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
08:19A Pipeline to Characterize Structural Heart Defects in the Fetal Mouse
11:06Structural Characterization of Mannan Cell Wall Polysaccharides in Plants Using PACE
11:12Fluorescent Labeling of Drosophila Heart Structures
06:14Translational Rabbit Model of Chronic Cardiac Pacing