Related Experiment Video
Updated: Jan 20, 2026

Ultrasound Tissue Characterization of Human Achilles Tendon by Stability Quantification of Echo Patterns
Published on: September 5, 2025
Characterization of Hand Tendons Through High-Frequency Ultrasound Elastography
Abstract:
Tendon stiffness plays an important role in the tendon healing process, and many studies have indicated that measuring the shear wave velocity (SWV) on tendons relates to their stiffness. Because the thickness of hand tendons is a few millimeters, high-resolution imaging is required for visualizing hand tissues. However, the resolution of current ultrasound elastography systems is insufficient. In this study, a high-frequency (HF) ultrasound elastography system is proposed for measuring the SWVs of hand tendons. The HF ultrasound elastography system uses an external vibrator to create shear waves on hand tendons. Then, it uses a 40-MHz HF ultrasound array transducer with ultrafast ultrasound imaging technology to measure the SWV for characterizing hand tendons. A handheld device that combines a transducer and a vibrator allows the user to scan hand tissues. The biases of HF ultrasound elastography were measured in gelatin phantom experiments and were less than 6% compared to standard mechanical testing approach. Human experiments showed the ability to use HF ultrasound elastography to distinguish different SWVs of hand tendons. The SWVs were 0.73 ± 0.65 m/s and 1 ± 0.54 m/s for flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP), respectively, and 0.52 ± 0.14 m/s and 4.02 ± 0.77 m/s for extensor tendon under stretch and contraction conditions, respectively. The simplicity and convenience of the HF ultrasound elastography system for measuring hand tendon stiffness make it a promising tool for evaluating the severity of hand injuries and the performance of rehabilitation after hand injuries.
Related Concept Videos
08:11Ultrasound Tissue Characterization of Human Achilles Tendon by Stability Quantification of Echo Patterns
07:13Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
High-frequency Ultrasound Imaging of the Abdominal Aorta
High-frequency ultrasound systems are used to acquire high resolution images. Here, the use of a state-of-the-art system will be demonstrated to image the morphology and hemodynamics of small pulsatile arteries and veins found in mice and rats. Ultrasound is a relatively inexpensive, portable, and versatile method for the noninvasive...
07:04A Novel Use of Three-dimensional High-frequency Ultrasonography for Early Pregnancy Characterization in the Mouse
04:51Quantifying Elastic Properties of Environmental Biofilms using Optical Coherence Elastography
10:02High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes

