Related Experiment Video
Updated: Jan 20, 2026

Identification of Fatty Acids in Bacillus cereus
Published on: December 5, 2016
The effects of the analysis strategy on the correlation between the NIRS reperfusion measures and the FMD response
Rogério Nogueira Soares1, Gustavo Vieira de Oliveira2, Thiago Silveira Alvares2
1Faculty of Kinesiology, University of Calgary, 2500 University Dr. NW, Calgary, AB, Canada.
Abstract:
This study aimed to investigate the correlation between near-infrared spectroscopy (NIRS)-derived measures of microvascular responses using a range of different analysis and flow-mediated dilation (FMD). Additionally, we aimed to investigate whether assessing NIRS and FMD simultaneously or non-simultaneously would affect this association. Thirty-five healthy young individuals (26 ± 13 years old) participated in the study. Twenty were submitted to a simultaneous NIRS/FMD test (NIRS probe placed below the cuff during FMD test) and fifteen to a non-simultaneous FMD and NIRS intervention (NIRS test performed 20 min after FMD). NIRS-derived oxygen saturation signal (StO2) during reperfusion was analyzed as follow: upslope of a 10 s (slope 10 s) and 30 s (slope 30 s) reperfusion window immediately following cuff deflation, time for the StO2 to reach the pre-occlusion (baseline) values after cuff release (time to baseline) and to reach the peak after cuff release (time to max), difference between the minimum and maximum StO2 value reached after cuff deflation (Magnitude) and; the total area under the reperfusion curve above the baseline value until the end of the 2 min post cuff release (AUC 2 min). There was a significant positive correlation between slope 10 s and FMD in the simultaneous (r = 0.60; p < 0.05) and non-simultaneous (r = 0.62; p < 0.05) assessments. There was no significant correlation between NIRS-derived slope 30 s, time to baseline, time to max, magnitude, and AUC 2 min and the FMD in both methods. The association between NIRS and FMD is analysis strategy dependent, regardless if assessed simultaneously or non-simultaneously.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
10:59Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
Published on: February 7, 2025
Related Concept Videos
08:41Identification of Fatty Acids in Bacillus cereus
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
10:59Glycomics-Guided Glycoproteomics Facilitates Comprehensive Profiling of the Glycoproteome in Complex Tumor Microenvironments
10:33Correlating Behavioral Responses to fMRI Signals from Human Prefrontal Cortex: Examining Cognitive Processes Using Task Analysis
09:53Herbal Munziq Ameliorates Myocardial Ischemia-Reperfusion Injury by Inhibiting Inflammation
07:52Multiplexed Fluorescent Immunohistochemical Staining, Imaging, and Analysis in Histological Samples of Lymphoma