Related Experiment Video
Updated: Jan 20, 2026

Orthotopic Left Lung Transplantation in Rats
Published on: July 3, 2025
The Wythenshawe Hybrid Circuit for lung transplantation: a previously undescribed circuit for lung transplant
Andrew Brazier1, Edward Seville1, Wesley Hesford1
1Department of Cardiothoracic and Transplant Surgery, Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester, UK.
Abstract:
Extracorporeal membrane oxygenation is a safe modality of cardiorespiratory support for lung transplantation, with a reduction in coagulopathy and transfusion requirement when compared with cardiopulmonary bypass. In some scenarios, in lung transplantation, there are advantages to the use of cardiopulmonary bypass, which allows cardiac decompression, filtering of embolic air, easy addition and removal of volume, and a means to immediately reintroduce lost blood into circulation. We describe a novel circuit which allows safe and easy switch between modalities without prolonged interruption of flow. This circuit offers a safety net during surgery to minimise the risks influencing the use of extracorporeal membrane oxygenation.
Related Concept Videos
08:22Orthotopic Left Lung Transplantation in Rats
07:28Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
08:37Blood Circuit Reconstruction in an Abdominal Mouse Heart Transplantation Model
06:55Left Lung Orthotopic Transplantation in a Juvenile Porcine Model for ESLP
04:16Intravital Two-Photon Microscopy of the Transplanted Mouse Lung
07:37A Rat Lung Transplantation Model of Warm Ischemia/Reperfusion Injury: Optimizations to Improve Outcomes