Expression of concern: Ligand discrimination of myoglobin in solution: an iron L-edge X-ray absorption study of the

Richard Kelly1

  • 1Royal Society of Chemistry, Thomas Graham House, Science Park, Milton Road, Cambridge, CB4 0WF, UK. chemcomm-rsc@rsc.org.

Chemical Communications (Cambridge, England)
|September 5, 2019
PubMed

Related Concept Videos

Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering07:55

Elemental-sensitive Detection of the Chemistry in Batteries through Soft X-ray Absorption Spectroscopy and Resonant Inelastic X-ray Scattering

Here, we present a protocol for typical experiments of soft X-ray absorption spectroscopy (sXAS) and resonant inelastic X-ray scattering (RIXS) with applications in battery material...
13.2K
Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating10:39

Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating

The measurement protocol and data analysis procedure are given for obtaining transverse coherence of a synchrotron radiation X-ray source along four directions simultaneously using a single 2-D checkerboard phase grating. This simple technique can be applied for complete transverse coherence characterization of X-ray sources and X-ray...
10.1K
Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy06:00

Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy

This protocol presents a detailed procedure to prepare biological cryosamples for synchrotron-based X-ray absorption spectroscopy experiments. We describe all the steps required to optimize sample preparation and cryopreservation with examples of the protocol with cancer and phytoplankton cells. This method provides a universal standard of sample...
3.0K
Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence06:27

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence

This protocol describes the procedure to express fresh pore solution from cementitious systems and the measurement of its ionic composition using X-ray fluorescence. The ionic composition can be used to calculate pore solution electrical resistivity, which can be used, together with concrete electrical resistivity, to determine the formation...
9.8K
Expressing Solution Concentration02:48

Expressing Solution Concentration

A solute is a component of a solution that is typically present at a much lower concentration than the solvent. Solute concentrations are often described with qualitative terms such as dilute (of relatively low concentration) and concentrated (of relatively high concentration).
Concentrations may be quantitatively assessed using a wide variety of measurement units, each convenient for particular applications. Molarity (M) is a useful concentration unit for many applications in chemistry.
66.0K
Small and Wide Angle X-Ray Scattering Studies of Biological Macromolecules in Solution12:53

Small and Wide Angle X-Ray Scattering Studies of Biological Macromolecules in Solution

The demonstration of the small and wide angle X-ray scattering (SWAXS) procedure has become instrumental in the study of biological macromolecules. Through the use of the instrumentation and procedures of specific angle methods and preparation, the experimental data from the SWAXS displays the atomic and nano-scale characterization of...
18.7K