Related Experiment Video
Updated: Jan 20, 2026

Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
Published on: April 20, 2021
A comparative evaluation of cataract classifications based on shear-wave elastography and B-mode ultrasound findings
Mesut Ozgokce1, Muhammed Batur2, Muhammed Alpaslan3
1Department of Radiology, Medical Faculty, Yuzuncu Yıl University, 65100, Van, Turkey. mozgokce@gmail.com.
Abstract:
In this study, a comparison is made of the findings of B-mode ultrasound and ultrasound elastography with the Lens Opacities Classification (LOCS) grade in patients with senile cataracts. A total of 74 patients with cataracts and 32 age-matched healthy volunteers as the control group were evaluated in the departments of ophthalmology and radiology between 2016 and 2017. In the patient group, cataracts were graded according to LOCS, and B-mode sonographic appearance and elasticity measurements were recorded, after which the cataract grade and sonoelastography/B-mode ultrasound findings were compared using statistical methods. Among the 74 patients with cataracts, 38 were females (51.4%) and 36 were males (48.6%), and the mean age was 62.05 ± 7.95 (43-78) years. A Chi-square test revealed a significant relationship between ultrasound echogenicity of cataract and grade of cataract (p < 0.005). The ultrasound elastography revealed a mean shear-wave velocity of 2.90 m/s ± 0.371 (2.13-3.53) among patients with grade 3 cataracts, 3.1 m/s ± 0.45 (2.26-3.98) among patients with grade 4, 3 m/s ± 0.58 (2.35-4.60) among patients with grade 5 and 3 m/s ± 0.528 (2.31-4.50) among patients with grade 6 cataracts, and 3 m/s ± 0.258 (2.36-3.58) among the normal subjects. No statistically significant difference was noted in the analysis of variance (p > 0.005). While cataract grade and B mode echogenicity were directly proportional, there was no significant difference in lens elasticity.
Related Concept Videos
07:13Application of Ultrasound and Shear Wave Elastography Imaging in a Rat Model of NAFLD/NASH
05:56Implementation of Non-invasive Point of Care Transient Elastography for Evaluation of Liver Disease in Pediatric Populations with Cystic Fibrosis
08:07Ultrasound-based Pulse Wave Velocity Evaluation in Mice
Magnetic Resonance Elastography for Assessing Viscoelastic Properties
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
Modes of Standing Waves - I

