Related Experiment Video
Updated: Jan 20, 2026

Measuring In Vitro ATPase Activity for Enzymatic Characterization
Published on: August 23, 2016
Effect of a multi-frequency counter-current S-type ultrasound pretreatment on the defatted corn germ protein:
Abubakr Musa1, Mohammed A A Gasmalla2, Haile Ma3
1School of Food and Biological Engineering, Jiangsu University, 301 Xuefu Road, Zhenjiang, Jiangsu 212013, China. mhl@ujs.edu.cn abmuah@hotmail.com and Sugar Institute, University of Gezira, P. O. Box 20, Wad Madani, Al Gezira, Sudan.
Abstract:
In this work, a defatted corn germ protein (DCGP) was pretreated with single frequency ultrasound at 20 kHz (SFU) and multi-frequency ultrasounds (20, 28, 35 and 40 kHz) (MFU). The microstructures, morphology, amino acid content, degree of hydrolysis, protein hydrolysate concentration and angiotensin-converting enzyme (ACE) inhibitory activity of the DCGP hydrolysate were analyzed. The results showed that both SFU and MFU pretreatments increased the ACE inhibitory activity of the DCGP hydrolysate more than that observed for the traditional method. Also, the SFU pretreatment showed the highest ACE inhibitory activity of 54% in comparison with that of the DCGP hydrolysates obtained via the traditional and MFU pretreatment methods. The results of ultraviolet-visible (UV-Vis) spectroscopy, fluorescence spectroscopy, surface hydrophobicity studies, Fourier-transform infrared spectroscopy (FTIR), atomic force microscopy (AFM) and scanning electron microscopy (SEM) confirmed the extent of the changes that occurred in the microstructures and morphology of DCGP pretreated with SFU and MFU. The results also indicated that the hydrophobic amino acid concentration was comparably higher in DCGP pretreated with SFU and MFU than that in the DCG protein isolated via the traditional method.
Related Concept Videos
07:38Measuring In Vitro ATPase Activity for Enzymatic Characterization
06:02Multi-timescale Microscopy Methods for the Characterization of Fluorescently-labeled Microbubbles for Ultrasound-Triggered Drug Release
06:01A Dye Release Assay to Quantify Enzymatic Activity of Antimicrobial Proteins
09:30Ammonia Fiber Expansion (AFEX) Pretreatment of Lignocellulosic Biomass
14:45Transgenic Rodent Assay for Quantifying Male Germ Cell Mutant Frequency
High-frequency Ultrasound Imaging of the Abdominal Aorta
High-frequency ultrasound systems are used to acquire high resolution images. Here, the use of a state-of-the-art system will be demonstrated to image the morphology and hemodynamics of small pulsatile arteries and veins found in mice and rats. Ultrasound is a relatively inexpensive, portable, and versatile method for the noninvasive...

