Related Experiment Video
Updated: Jan 20, 2026

The Corneal Micropocket Assay: A Model of Angiogenesis in the Mouse Eye
Published on: August 16, 2014
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes:
Adimara da Candelaria Renesto1, Flávio E Hirai1, Mauro Campos1
1Departamento de Oftalmologia e Ciências Visuais, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Purpose:
This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%.
Methods:
Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups.
Results:
The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01).
Conclusions:
Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.
More Related Videos
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
Published on: February 14, 2015
05:36Subjective Refraction Test Using a Smartphone for Vision Screening
Published on: October 18, 2024
Related Concept Videos
11:49The Corneal Micropocket Assay: A Model of Angiogenesis in the Mouse Eye
03:24Anterior Eye Segment Dissection: A Method to Isolate Cornea Bearing Anterior Segment from Porcine Eye
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
03:57Anterior Eye Segment Culturing: A Method to Culture Cornea Bearing Anterior Segment of Porcine Eye
Reflection and Refraction
Light travels at different speeds depending on the material through which it is propagating. When light travels from one material to another, it will either slow down or speed up. In order to conserve energy and momentum, the light must change the direction in which it propagates. This bending of light is known as refraction. Some fraction of...
05:36Subjective Refraction Test Using a Smartphone for Vision Screening