Clinical Advantages of Using Low Tube Voltage in Third-Generation 192-Slice Dual-Source Computed Tomographic
Hiroshi Onoda1, Hiroshi Ueno1, Masahiko Hashimoto2
1Second Department of Internal Medicine, University of Toyama.
Abstract:
Low-voltage computed tomographic angiography (CTA) is a highly effective technique to reduce contrast media volume. We sought to examine the suitability of low tube voltage CTA with a reduced contrast media volume protocol using third-generation 192-slice dual-source CT in patients undergoing transcatheter aortic valve implantation (TAVI). CTA was performed to aid TAVI planning for 40 consecutive patients with severe aortic stenosis. For the first 10 patients (120/100 kV group), we used a conventional tube voltage combined CTA protocol (an ECG-gated helical scan; 120 kV, non-gated helical scan; 100 kV). For the subsequent 30 patients (70-kV group), we adopted a low tube voltage CTA protocol. We evaluated vascular attenuation, image noise, contrast-to-noise ratio (CNR), and renal function. The mean contrast media (CM) volume was 77.7 ± 17.7 mL in the 120/100-kV group and 30.9 ± 6.3 mL in the 70-kV group (P < 0.001). In the images of the aortic valve complex, the mean attenuation was not significant difference for both groups. In the images of the aorto-femoral arteries, mean attenuation was > 250 Hounsfield Units and CNR was > 10 in all vascular segments for both groups. There was no significant difference in the change of renal function in the 70-kV group, but renal function in the 120/100-kV group decreased within 1-3 months after CTA. Low tube voltage CTA using third-generation dual-source CT is suitable to assess procedural planning for TAVI. This approach maintains image quality and reduces the required CM volume.
More Related Videos
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
06:04Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging