Related Experiment Video
Updated: Jan 20, 2026

A Pipeline to Characterize Structural Heart Defects in the Fetal Mouse
Published on: December 16, 2022
On the defect tolerance of fetal membranes
Kevin Bircher1, Alexander E Ehret1,2, Deborah Spiess3
1ETH Zurich, Institute for Mechanical Systems, 8092 Zurich, Switzerland.
Abstract:
A series of mechanical experiments were performed to quantify the strength and fracture toughness of human amnion and chorion. The experiments were complemented with computational investigations using a 'hybrid' model that includes an explicit representation of the collagen fibre network of amnion. Despite its much smaller thickness, amnion is shown to be stiffer, stronger and tougher than chorion, and thus to determine the mechanical response of fetal membranes, with respect to both, deformation and fracture behaviour. Data from uniaxial tension and fracture tests were used to inform and validate the computational model, which was then applied to rationalize measurements of the tear resistance of tissue samples containing crack-like defects. Experiments and computations show that the strength of amnion is not significantly reduced by defects smaller than 1 mm, but the crack size induced by perforations for amniocentesis and fetal membrane suturing during fetal surgery might be larger than this value. In line with previous experimental observations, the computational model predicts a very narrow near field at the crack tip of amnion, due to localized fibre alignment and collagen compaction. This mechanism shields the tissue from the defect and strongly reduces the interaction of multiple adjacent cracks. These findings were confirmed through corresponding experiments, showing that no interaction is expected for multiple sutures for an inter-suture distance larger than 1 mm and 3 mm for amnion and chorion, respectively. The experimental procedures and numerical models applied in the present study might be used to optimize needle and/or staple dimensions and inter-suture distance, and thus to reduce the risk of iatrogenic preterm premature rupture of the membranes from amniocentesis, fetoscopic and open prenatal surgery.
Related Concept Videos
08:19A Pipeline to Characterize Structural Heart Defects in the Fetal Mouse
08:04Murine Fetal Echocardiography
07:37Isolation of Primary Human Decidual Cells from the Fetal Membranes of Term Placentae
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
06:31Transuterine Fetal Tracheal Occlusion Model in Mice
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...

