Turbidity and Total Solids in Surface Water
Published on: April 30, 2023
Determining suspended solids and total phosphorus from turbidity: comparison of high-frequency sampling with
Ana Villa1, Jens Fölster2, Katarina Kyllmar3
1Department of Soil and Environment, Swedish University of Agricultural Sciences, P.O. Box 7014, 75007, Uppsala, Sweden. ana.villa@slu.se.
Abstract:
Suspended solids (SS) are important carriers of pollutants such as phosphorus (P) in streams, but the sampling frequency in monitoring programs is usually insufficiently frequent to capture episodic SS and total P (TP) peaks. The suitability of turbidity and conductivity as a surrogate for SS and TP was studied using 108 monitoring stations located in catchments of different sizes, land uses, and pollution levels. The use of high-frequency turbidity measurements to estimate SS and TP loads was compared with the use of two sampling methods (grab, flow-proportional sampling) in a case study. When all samples were considered, turbidity was a good predictor of SS (r2 = 0.76) and TP (r2 = 0.75). For single sites, there was a large range in how well turbidity could predict the two variables. The site-specific turbidity-SS relationship was significant at 87% of sites (mean r2 = 0.72). The site turbidity and conductivity-TP relationship was significant at 78% of sites (mean r2 = 0.62). A stronger turbidity-SS relationship was found in catchments with a higher percentage of agricultural land. The turbidity and conductivity-TP relationship was stronger when the TP concentration was high. In the case study, TP loads were smallest when estimated with grab sampling, which missed several discharge peaks. Loads estimated with high-frequency turbidity measurements were 19-51% smaller than with flow-proportional sampling, probably due to differences in sampling points. High-frequency turbidity measurements can be a viable alternative to conventional sampling methods in studies on concentration dynamics and load estimates.
More Related Videos
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
10:49Laboratory-determined Phosphorus Flux from Lake Sediments as a Measure of Internal Phosphorus Loading
Published on: March 6, 2014
Related Concept Videos
Turbidity and Total Solids in Surface Water
Turbidity and total solids are related measurements addressing clarity of surface waters. Turbidity is an indirect measure of water clarity that determines the amount of light that can pass through the water. Total solids is a direct measurement of solid particles suspended in water determined by weight.
High levels of turbidity and total solids are caused by soil erosion, waste discharge, runoff, or changes in...
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
10:49Laboratory-determined Phosphorus Flux from Lake Sediments as a Measure of Internal Phosphorus Loading
Molecular Comparison of Gases, Liquids, and Solids
05:18High-Resolution Comparison of Bacterial Conjugation Frequencies
Determining the Density of a Solid and Liquid
The ratio of the mass of a substance to its volume is known as the mass density or, simply, the density of the substance. Density is expressed in units of mass per volume, such as g/mL or kg/m3. Because the density of a substance does not depend on the amount of substance present, density is an “intensive property”.
To measure the density of a sample of material, both the mass and volume of the sample...