Applicability of Low-Cost Binders for the Quantitative Elemental Analysis of Urinary Stones Using EDXRF Based on
Abdallah A Shaltout1,2, Maram M Dabi3, Mohamed M Ibrahim4,5
1Spectroscopy Department, Physics Division, National Research Centre, El Behooth St., 12622 Dokki, Cairo, Egypt. shaltout_a@hotmail.com.
Abstract:
The pressed powder sample is a common method for elemental analysis using X-ray fluorescence analysis whereas suitable light hydrocarbon materials should be added to the sample as a binder. The present study demonstrates the applicability of using different commercial binders for elemental analysis of urinary stone samples. In order to confirm the obtained results, a comparison with pure chemical grade binders was presented. Different commercial and pure binders were tested for quantitative elemental analysis of urinary stones, namely, cellulose, starch, wax, and urea. Energy dispersive X-ray fluorescence (EDXRF) was used for elemental analysis. Differential thermal analysis was used to estimate the loss on ignition (LOI) in the urinary stone samples. The signal to background ratios (I/IB) of the different detected elements in the commercial and pure binders were calculated, compared, and studied at eight different photon energies starting from 2.5 up to 37 keV. Standard-less quantitative analysis method based on the fundamental parameter approach was applied for elemental analysis of selected urinary stones. The commercial and low-cost binders could be an excellent alternative binder for urinary stone analysis using energy dispersive X-ray fluorescence. The commercial binders could provide an advantage as pure chemical grade binders or even better especially at photon energy higher than 10 keV. The best commercial binder candidate was found to be the wax. The quantitative analysis results using commercial and pure chemical grade binders give good agreement results, which indicate the applicability of commercial binders for quantitative elemental analysis of urinary stones in the form of pressed powder samples.
Related Concept Videos
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
07:57Electrospinning Fundamentals: Optimizing Solution and Apparatus Parameters
10:50Computational Modeling of Retinal Neurons for Visual Prosthesis Research - Fundamental Approaches
09:20Lumped-Parameter and Finite Element Modeling of Heart Failure with Preserved Ejection Fraction
08:04A New Approach for the Comparative Analysis of Multiprotein Complexes Based on 15N Metabolic Labeling and Quantitative Mass Spectrometry
10:40A Fabrication and Measurement Method for a Flexible Ferroelectric Element Based on Van Der Waals Heteroepitaxy