Differentiating Nutrient Artery Canals of the Femur versus Fracture Lines in Patients with Total Hip Arthroplasty on

Ho Hyun Yun1, Gi Won Choi2, Wan Tae Kim3

  • 1Department of Orthopaedic Surgery, Seoul Veterans Hospital, Seoul, South Korea.

Abstract

Related Concept Videos

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty09:31

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty

This protocol describes the round-the-corner technique and the individualized stem-positioning of calcar-guided short stems alongside the medial calcar, depending on the level of the osteotomy. This differs from conventional total hip arthroplasty and includes a learning...
12.4K
Establishing a Diaphyseal Femur Fracture Model in Mice05:46

Establishing a Diaphyseal Femur Fracture Model in Mice

This protocol describes a surgical procedure for the establishment of a diaphyseal fracture in the femur of mice, which is stabilized with an intramedullary wire, for fracture healing...
3.0K
Reverse Total Shoulder Arthroplasty10:10

Reverse Total Shoulder Arthroplasty

Reverse total shoulder arthroplasty is indicated for the treatment of conditions that cannot be treated with conventional arthroplasty or other procedures. These primarily include degenerative and incapacitating conditions with irreparable rotator cuff and loss of the normal biomechanical coupling of the shoulder.
43.8K
Transverse Fracture of the Mouse Femur with Stabilizing Pin03:57

Transverse Fracture of the Mouse Femur with Stabilizing Pin

This protocol describes a method to perform fractures on adult mice and monitor the healing...
4.1K
A Method to Estimate Cadaveric Femur Cortical Strains During Fracture Testing Using Digital Image Correlation09:34

A Method to Estimate Cadaveric Femur Cortical Strains During Fracture Testing Using Digital Image Correlation

In this protocol, the femur surface strains are estimated during fracture testing using the digital image correlation technique. The novelty of the method involves application of a high-contrast stochastic speckle pattern on the femur surface, carefully specified illumination, high speed video capture, and digital image correlation analysis for strain calculations.
7.8K
Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner04:41

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner

Here, we present a protocol for accessing the guidewire of intramedullary femoral nailing in obese patients using an in-house designed awl. Using the new awl with a distal positioner for the guidewire insertion and opening the bone can increase efficiency in inserting the guidewire and reduce the difficulty of...
930