Related Experiment Video
Updated: Jan 20, 2026

A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties
Published on: January 7, 2017
Thermal damage thresholds for multiple-pulse porcine skin laser exposures at 1070 nm
Michael P DeLisi1, Morgan S Schmidt2, Aaron F Hoffman2
1SAIC, JBSA Fort Sam Houston, Texas, United States.
Abstract:
As solid-state laser technology continues to mature, high-energy lasers operating in the near-infrared (NIR) band have seen increased utilization in manufacturing, medical, and military applications. Formulations of maximum permissible exposure limits establish guidelines for the safe use of these systems for a given set of laser parameters, based on past experimental and analytical studies of exposure thresholds causing injury to the skin and eyes. The purpose of our study is to characterize the skin response to multiple-pulsed laser exposures at the NIR wavelength of 1070 nm, at a constant beam diameter of 1 cm, using anesthetized Yucatan mini-pig subjects. Our study explores three constant total laser-on times of 0.01, 0.1, and 10 s as single- and multiple-pulse sequences. Exposures consisting of 10, 30, and 100 pulses have identical individual pulse durations but different duty cycles in order to include variable degrees of thermal additivity. A plurality of three observers quantifies skin damage with the minimally visible lesion metric, judged at the 1- and 24-h intervals postexposure. Calculation of the median effective dose (ED50) provides injury thresholds for all exposure conditions, based on varying laser power across subjects. The results of this study will provide a quantitative basis for the incorporation of multiple-pulsed laser exposure into standards and augment data contained in the existing ED50 database.
Related Concept Videos
08:41A Rapid Laser Probing Method Facilitates the Non-invasive and Contact-free Determination of Leaf Thermal Properties
Thermal Diffusivity and the Laser Flash Method
The laser flash method (LFA) is a technique used to measure thermal diffusivity, a material specific property. Thermal diffusivity (α) is the ratio of how much heat is conducted relative to how much heat is stored in a material. It is related to thermal conductivity (), how much heat is transferred through a material due to a temperature...
09:49Continuous-wave Thulium Laser for Heating Cultured Cells to Investigate Cellular Thermal Effects
07:12Assessment of Sensory Thresholds in Dogs Using Mechanical and Hot Thermal Quantitative Sensory Testing
13:21Determining heat and mechanical pain threshold in inflamed skin of human subjects
04:11Laser-assisted Selective Ablation of Porcine Corneal Endothelial Cells: A Technique to Induce Focused Porcine Corneal Endothelial Injury for Ex Vivo Studies