Related Experiment Video
Updated: Jan 20, 2026

Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
Selective determination of some beta-blockers in urine and plasma samples using continuous flow membrane
Atefeh Mahmoudi1, Maryam Rajabi1
1Department of Chemistry, Semnan University, Semnan 2333383-193, Iran.
Abstract:
In this work, an efficient method termed as continuous flow membrane microextraction coupled with high performance liquid chromatography is introduced for a highly selective determination of metoprolol and propranolol in the biological samples. According to this method, an aqueous source phase of the analytes (donor phase, 10 mL) is circulated into an extraction cell, which is separated from an aqueous acceptor phase (100 μL) by a small piece of polypropylene membrane sheet whose pores are impregnated by an organic solvent (1-octanol, 15 μL). The analytes are extracted from the donor phase into the organic solvent. They are subsequently selectively back-extracted into the acceptor solution due to the pH gradient. The proposed method is very convenient and has the capability of being fully automated. It provides a good preconcentration and an excellent repeatability. The extractant is an aqueous phase, and by prevention of the extraction of macromolecules through the membrane, the developed method provides a high sample clean-up. In order to maximize the extraction efficiency, the influential parameters including the type of mediator solvent, pH values for the donor and acceptor solutions, extraction time, ionic strength, stirring rate, and volume of the acceptor solution are optimized. The calibration curves were obtained with a reasonable linearity (r2 = 0.999) in the range of 3-1000 ng mL-1. The limits of detection were 0.5 and 1.0 ng mL-1, and excellent relative standard deviations were obtained (between 3.2% and 4.0%). Finally, the reliability of the procedure is evaluated by determination of metoprolol and propranolol in the human urine and plasma samples, which indicates the suitability, sensitivity, and high sample clean-up of the proposed method.
Related Concept Videos
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
High-Performance Liquid Chromatography (HPLC)
High-performance liquid chromatography (HPLC) is an important analytical method commonly used to separate and quantify components of liquid samples. In this technique, a solution (first phase) is pumped through a column that contains a packing of small porous particles with a second phase bound to the surface. The different solubilities of the sample components in the two phases cause the components to move through the column with different average...
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
11:01Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
