Related Concept Videos

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial03:07

Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial

This prospective study evaluated the implementation of a novel, single-port, robotic platform in oncoplastic breast-conserving surgery for malignant lesions. The primary endpoint focused on technical success, defined as the achievement of tumor-free resection margins confirmed by intraoperative frozen-section histopathology, with secondary assessment of aesthetic outcomes and life quality score of...
842
Dynamic Navigation for Dental Implant Placement05:42

Dynamic Navigation for Dental Implant Placement

Dynamic computer-aided implant surgery (DCAIS) is a controlled implant surgical placement method performed without a surgical template using optical control. The real-time intraoperative control of movement and position of the surgical device simplifies the procedure and gives more freedom to the surgeon, providing similar precision as static navigation methods.
4.4K
Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis06:03

Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis

Breast cancer related lymphedema is frequent in breast cancer survivors, but there are not widely employed guidelines for its diagnosis and quantification. Here, we introduce a reliable and cost-effective protocol to define, quantify, and compare upper limb volume in breast cancer...
7.0K
A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice06:27

A Retrograde Implantation Approach for Peritoneal Dialysis Catheter Placement in Mice

This article describes modifications of a procedure to implant a peritoneal dialysis catheter in a murine model to avoid major technical issues observed with the conventional...
3.1K
Blind Procedures02:07

Blind Procedures

Ideally, the people who observe and record the children’s behavior are unaware of who was assigned to the experimental or control group, in order to control for experimenter bias. Experimenter bias refers to the possibility that a researcher’s expectations might skew the results of the study. Remember, conducting an experiment requires a lot of planning, and the people involved in the research project have a vested interest in supporting their hypotheses. If the observers knew which...
13.0K
Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model06:18

Pedicle Screw Placement Using an Augmented Reality Head-Mounted Display in a Porcine Model

The augmented reality head-mounted display, Magic Leap, was used in combination with a conventional navigation system to place pedicle screws in a porcine model by adhering to a novel workflow. With a median insertion time of <2.5 min, submillimeter technical accuracy and 100% clinical accuracy were achieved according to...
2.6K