Purpose:
To perform a systematic review and meta-analysis regarding the performance of CT for diagnosis of bowel endometriosis.
Materials And Methods:
Pubmed and EMBASE were systematically searched up to March 28, 2019. Diagnostic accuracy studies using CT for diagnosis of bowel endometriosis using laparoscopy followed by histopathology as the reference standard were included. Methodological quality of the included studies was evaluated using Quality Assessment of Diagnostic Accuracy Studies-2. Sensitivity and specificity were pooled using hierarchical summary receiver operating modelling. Meta-regression analysis was done to explore heterogeneity.
Results:
Twelve studies (1091 patients) were included. Pooled sensitivity and specificity were 0.92 (95% confidence interval [CI], 0.83-0.97) and 0.95 (95% CI, 0.88-0.98), respectively. Substantial heterogeneity was present: I2 = 92.38% for sensitivity and 89.09% for specificity. Deeks' asymmetry test suggested publication bias (p = 0.04). At meta-regression analysis, history of prior surgery for endometriosis was the only significant factor affecting heterogeneity (p < 0.01). Specifically, studies that included patients with such history demonstrated significantly greater specificity than studies that did not (0.95 [95% CI, 0.91-1.00] vs 0.75 [95% CI, 0.43-1.00]).
Conclusions:
CT shows excellent performance in the diagnosis of bowel endometriosis. Due to small number of included studies and publication bias, further studies may be needed to validate these results.
Related Concept Videos
04:34Meta-Analysis of the Effectiveness and Safety of Shugan Jieyu Capsules for the Treatment of Insomnia
06:56Tree Core Analysis with X-ray Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
07:12A Syngeneic Murine Model of Endometriosis using Naturally Cycling Mice
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
08:36The Adjuvant Efficacy of Angong Niuhuang Pill in the Treatment of Viral Encephalitis: A Meta-Analysis of Randomized Controlled Trials