1Laboratorio de Desarrollo Analítico y Quimiometría (LADAQ), Cátedra de Química Analítica I, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral, Ciudad Universitaria, Santa Fe, S3000ZAA, Argentina; Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Godoy Cruz 2290 CABA, C1425FQB, Argentina; Departamento de Química Inorgánica, Analítica y Química Física, INQUIMAE, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Intendente Güiraldes 2160, Ciudad Universitaria, Pabellón 2, C1428EGA, Buenos Aires, Argentina.
Abstract:
The latest advances in both theory and experimental procedures on third-order/four-way and fourth-order/five-way calibration methods are discussed. This report is focused on excitation-emission (fluorescence and phosphorescence) matrices generation, employing different variables as the third data mode (time retention in chromatography, pH gradient, fluorescence/phosphorescence lifetime, kinetics, or other chemical treatments). Fully capitalizing on the second-order advantage, it has been possible to develop appealing analytical applications in spite of the complexity of the data. Extraction of the significant chemical information about the system under study as well as the individual abundance of the contributing constituents after proper higher-order data decomposition has allowed to analytical researchers performing quantitative analysis of complex samples. The experimental works reported up to the present are introduced and discussed in order to illustrate concepts. Throughout this work, the analytical benefits achieved by modeling third- and fourth-order data are exposed, attempting to contribute to the ongoing debate in the chemometric community regarding the existence and the true nature of the third-order advantage.
Related Concept Videos
07:04A Step Beyond BRET: Fluorescence by Unbound Excitation from Luminescence (FUEL)
08:35Luminescence Lifetime Imaging of O2 with a Frequency-Domain-Based Camera System
07:46Data Acquisition Protocol for Determining Embedded Sensitivity Functions
07:12Synthesis of Persistent Luminescent Nanoparticles for Rewritable Displays and Illumination Applications
07:13Nanostructured Ag-zeolite Composites as Luminescence-based Humidity Sensors
10:58Facilitating the Analysis of Immunological Data with Visual Analytic Techniques