Related Experiment Video
Updated: Jan 19, 2026

A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique
Published on: April 26, 2015
Enhanced monitoring during neonatal resuscitation
Georg M Schmölzer1, Colin J Morley2, Omar C O F Kamlin3
1Centre for the Studies of Asphyxia and Resuscitation, Neonatal Research Unit, Royal Alexandra Hospital, Edmonton, Alberta, Canada; Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.
Immediately after birth through spontaneous breaths, infants' clear lung liquid replacing it with air, and gradually establishing a functional residual capacity to achieve gas exchange. Most infants start breathing independently after birth and ~3% of infants who require positive pressure ventilation. When newborns fail to start breathing the current neonatal resuscitation guidelines recommend initiatingpositive pressure ventilationusing a face mask and a ventilation device. Adequate ventilation is the cornerstone of successful neonatal resuscitation; therefore, it is mandatory that anybody involved in neonatal resuscitation is trained in mask ventilation techniques. One of the main problems with mask ventilation is that it is very subjective with direct feedback lacking and not uncommonly, the resuscitator does not realise that their technique is unsatisfactory. Many studies have shown that monitoring tidal volume and leak around the mask or endotracheal tube enables the resuscitator to identify the problem and adjust their technique to reduce the leak and deliver and appropriate tidal volume. This chapter discusses the currently available monitoring devices used during stabilization/resuscitation in the delivery room.
Immediately after birth through spontaneous breaths, infants' clear lung liquid replacing it with air, and gradually establishing a functional residual capacity to achieve gas exchange. Most infants start breathing independently after birth and ~3% of infants who require positive pressure ventilation. When newborns fail to start breathing the current neonatal resuscitation guidelines recommend initiatingpositive pressure ventilationusing a face mask and a ventilation device. Adequate ventilation is the cornerstone of successful neonatal resuscitation; therefore, it is mandatory that anybody involved in neonatal resuscitation is trained in mask ventilation techniques. One of the main problems with mask ventilation is that it is very subjective with direct feedback lacking and not uncommonly, the resuscitator does not realise that their technique is unsatisfactory. Many studies have shown that monitoring tidal volume and leak around the mask or endotracheal tube enables the resuscitator to identify the problem and adjust their technique to reduce the leak and deliver and appropriate tidal volume. This chapter discusses the currently available monitoring devices used during stabilization/resuscitation in the delivery room.
More Related Videos
05:58Application of an Amplitude-integrated EEG Monitor Cerebral Function Monitor to Neonates
Published on: September 6, 2017
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
Published on: January 13, 2023
Related Concept Videos
09:47A Rat Model of Ventricular Fibrillation and Resuscitation by Conventional Closed-chest Technique
05:58Application of an Amplitude-integrated EEG Monitor (Cerebral Function Monitor) to Neonates
10:55A Piglet Perinatal Asphyxia Model to Study Cardiac Injury and Hemodynamics after Cardiac Arrest, Resuscitation, and the Return of Spontaneous Circulation
07:18Mouse Cardiac Arrest Model for Brain Imaging and Brain Physiology Monitoring During Ischemia and Resuscitation
09:03The Perinatal Asphyxiated Lamb Model: A Model for Newborn Resuscitation
06:04Ultrasonographic Assessment During Cardiopulmonary Resuscitation