Clinical implications of LDH isoenzymes in hemolysis and continuous-flow left ventricular assist device-induced

Jonathan S Gordon1, Chelsey T Wood1, Jessica G Y Luc2

  • 1Division of Cardiac Surgery, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania.

Artificial Organs
|September 9, 2019
PubMed

Insights

Diagnosing pump thrombosis in continuous-flow left ventricular assist devices (CF-LVADs) is challenging. Analyzing lactate dehydrogenase (LDH) isoenzymes offers a promising method to differentiate pump thrombosis from other conditions.

Area of Science:

  • Biomedical Engineering
  • Cardiovascular Research
  • Clinical Diagnostics

Background:

  • Pump-induced thrombosis is a critical complication of continuous-flow left ventricular assist devices (CF-LVADs), leading to severe adverse events like stroke and pump failure.
  • Accurate diagnosis of CF-LVAD pump thrombosis is difficult due to the lack of direct measurement methods during device support.
  • Elevated lactate dehydrogenase (LDH) is used to suspect thrombosis, but it is a nonspecific marker.

Purpose of the Study:

  • To review the utility of lactate dehydrogenase (LDH) isoenzymes in differentiating hemolysis caused by CF-LVAD pump thrombosis from other conditions.
  • To highlight the diagnostic value of specific LDH isoenzyme patterns in CF-LVAD complications.

Main Methods:

  • Literature review of studies investigating lactate dehydrogenase (LDH) isoenzymes in the context of continuous-flow left ventricular assist device (CF-LVAD) pump thrombosis.
  • Analysis of reported LDH isoenzyme profiles associated with CF-LVAD pump thrombosis and other hemolytic conditions.

Main Results:

  • Continuous-flow left ventricular assist device (CF-LVAD) pump thrombosis is associated with specific lactate dehydrogenase (LDH) isoenzyme patterns, including elevated LDH-1 and LDH-2.
  • Decreased levels of LDH-4 and LDH-5 are also observed in CF-LVAD pump thrombosis.
  • These specific LDH isoenzyme profiles may help distinguish pump thrombosis-related hemolysis from other causes.

Conclusions:

  • Lactate dehydrogenase (LDH) isoenzyme analysis provides a more specific diagnostic approach for identifying pump-induced thrombosis in continuous-flow left ventricular assist devices (CF-LVADs).
  • Understanding LDH isoenzyme patterns is crucial for clinicians to accurately diagnose and manage CF-LVAD complications, improving patient outcomes.

Related Concept Videos

In Vitro Thrombosis Test for Ventricular Assist Devices09:15

In Vitro Thrombosis Test for Ventricular Assist Devices

We present a benchtop protocol to induce thrombosis in ventricular assist devices (VAD) within a recirculating test platform. This method serves to identify thrombogenic hotspots in the blood flow path and can help improve thromboresistance ahead of preclinical testing in animal...
1.2K
Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock07:39

Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock

The following article describes the stepwise procedure for placement of a device (e.g., Tandemheart) in cardiogenic shock (CS) that is a percutaneous left ventricular assist device (pLVAD) and a left atrial to femoral artery bypass (LAFAB) system that bypasses and supports the left ventricle (LV) in CS.
4.1K
Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart08:49

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart

Here, we present a protocol using two centrifugal pumps as a total artificial heart...
9.9K
Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock06:10

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock

Percutaneous ventricular assist devices are increasingly being utilized in patients with acute myocardial infarction and cardiogenic shock. Herein, we discuss the mechanism of action and hemodynamic effects of such devices. We also review algorithms and best practices for the implantation, management and weaning of these complex...
3.6K
Ferric Chloride-induced Murine Thrombosis Models10:37

Ferric Chloride-induced Murine Thrombosis Models

We report a refined procedure of the ferric chloride (FeCl3)-induced thrombosis models on carotid and mesenteric artery as well as vein, characterized efficiently using intravital microscopy to monitor time to occlusive thrombi...
23.0K
Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice07:55

Echocardiographic Characterization of Left Ventricular Structure, Function, and Coronary Flow in Neonate Mice

The present protocol describes the echocardiographic assessment of left ventricular morphology, function, and coronary blood flow in 7-day old neonate mice.
3.6K