Related Experiment Video
Updated: Jan 19, 2026

Sample Drift Correction Following 4D Confocal Time-lapse Imaging
Published on: April 12, 2014
Simultaneous respiratory motion correction and image reconstruction in 4D-multi pinhole small animal SPECT
Maryam Naseri1,2, Hossein Rajabi2, Jing Wang3
1Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA.
Purpose:
Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory motion amplitude. Small animals imaging systems with sub-millimeter spatial resolution need more attention to the respiratory motion for quantitative studies. We developed a motion-embedded four-dimensional (4D)-multi pinhole SPECT (MPS) reconstruction algorithm for respiratory motion correction. This algorithm makes full use of projection statistics for reconstruction of every individual frame.
Methods:
The ROBY phantom with small tumors in liver was generated in eight different phases during one respiratory cycle. The MPS projections were modeled using a fast ray tracing method simulating an MPS acquisition. Individual frames were reconstructed and used for motion estimation. The Demons non-rigid registration algorithm was used to calculate deformation vector fields (DVFs) for simultaneous motion correction and image reconstruction. A motion-embedded 4D-MPS method was used to reconstruct images using all the projections and corresponding DVFs, simultaneously. The 4D-MPS reconstructed images were compared to the low-count single frame (LCSF) reconstructed image, the three-dimensional (3D)-MPS images reconstructed using individual frames, and post reconstruction registration (PRR) that aligns all individual phases to a reference frame using Demons-derived DVFs. The tumor volume relative error (TVE), tumor contrast relative error (TCE), and dice index (DI) for 2, 3, and 4 mm liver were calculated and compared for different reconstruction methods.
Results:
For the 4D-MPS reconstruction method, TVE was reduced and DI was higher compared to PRR, 3D-MPS, and LCSF. The extent of the improvement was higher for the small tumor size (i.e. 2 mm). For the biggest tumor in contrast 3 (i.e. 4 mm) TVE for 4D-MPS, PRR, 3D-MPS and, LCSF were 1.33%, 8%, 8%, and 14.67%, respectively.
Conclusions:
The results suggest that motion-embedded 4D-MPS method is an effective and practical way for respiratory motion correction. It reconstructs high quality gated frames while using all projection data to reconstruct each frame.
Related Concept Videos
Combined SPECT and CT Imaging to Visualize Cardiac Functionality
Here we will demonstrate the fundamentals of single-photon emission computed tomography/computed tomography (SPECT/CT) imaging using mice. The technique involves injecting a radionuclide into a mouse, imaging the animal after it is distributed throughout the body, and then reconstructing the produced images to create a volumetric dataset. This can...
10:04Sample Drift Correction Following 4D Confocal Time-lapse Imaging
08:223D Cine Magnetic Resonance Imaging of Respiratory Motion in Mechanically Ventilated Mice and Rats
07:074D Light-sheet Imaging of Zebrafish Cardiac Contraction
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
12:384D Multimodality Imaging of Citrobacter rodentium Infections in Mice
