Retrospective analysis of an intraoperative aberrometry database: a study investigating absolute prediction in eyes
Robert J Cionni1, Michael Breen2, Cody Hamilton3
1The Eye Institute of Utah, Salt Lake City, UT, USA.
Purpose:
To evaluate the spherical equivalent outcomes of intraoperative aberrometry (IA) power calculations compared with the surgeons' preoperative power calculations in eyes implanted with AcrySof® IQ T3 intraocular lenses (IOLs).
Patients And Methods:
We assessed data collected by an IA system from multiple centers in the United States. Data was from patients who had undergone cataract extraction by phacoemulsification with the use of the Optiwave Refractive Analysis System and whose eyes had been implanted with model SN6AT3 (1.5 diopter [D] at IOL plane) aspheric lenses. The analysis was performed in 2 stages: hypothesis generation and confirmatory testing. Confirmatory endpoints were a comparison of absolute prediction errors for IA for the implanted IOL versus preoperative formula power calculations.
Design:
Retrospective analysis of preoperative, intraoperative, and postoperative data concerning eyes implanted with model SN6AT3 (1.5 D) aspheric lenses from the AnalyzOR™ database.
Results:
Mean absolute IA prediction error was significantly lower than preoperative prediction error (paired difference: -0.06 D; p<0.0001); this was mirrored by the median paired difference of -0.04 D (p<0.0001). For eyes where the power of the implanted IOL differed from the power of the preoperatively planned lens, mean and median paired differences in prediction errors were greater: -0.13 D (p<0.0001) and -0.15 D (p<0.0001), respectively. The percentage of eyes with prediction error ≤0.50 D was significantly higher with IA (83.4%, n=5388/6460) than with the preoperative formula (76.5%, n=4942/6460, p<0.0001). When the powers of the implanted IOL and the preoperatively planned lens were different, the percentage of eyes with prediction error ≤0.50 D was 83.3% (2155/2587) for IA and 68.8% (1781/2587, p<0.0001) for the preoperative formula.
Conclusion:
IA produces more accurate spherical equivalent outcomes for eyes implanted with a low toric IOL than the preoperative formulas.
More Related Videos
06:55Scanning Light Scattering Profiler SLPS Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
Published on: June 6, 2017
06:54Author Spotlight: Advancements in Impedance Monitoring for Cochlear Implant Surgery
Published on: August 4, 2023
Related Concept Videos
10:02Use of Rabbit Eyes in Pharmacokinetic Studies of Intraocular Drugs
06:55Scanning Light Scattering Profiler (SLPS) Based Methodology to Quantitatively Evaluate Forward and Backward Light Scattering from Intraocular Lenses
06:54Performing Repeated Intraoperative Impedance Telemetry Measurements during Cochlear Implantation
10:00Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
12:01Techniques for Processing Eyes Implanted With a Retinal Prosthesis for Localized Histopathological Analysis
09:14Paw-Dragging: a Novel, Sensitive Analysis of the Mouse Cylinder Test