Multimodality intravascular imaging of bioresorbable vascular scaffolds implanted in vein grafts
Tomasz Roleder1, Elzbieta Pociask2, Wojciech Wanha3
1Regional Specialist Hospital, Research and Development Center, Wroclaw, Poland.
Introduction:
There are no data presenting a serial assessment of vein graft healing after bioresorbable vascular scaffold (BVS) implantation at long-term follow-up.
Aim:
To describe ABSORB BVS healing in vein grafts by optical coherence tomography (OCT) and high-definition intravascular imaging (HD-IVUS) at long-term follow-up.Material and methods: The study group consisted of 6 patients. The first patient had serial OCT assessment of BVS implanted in the saphenous vein grafts (SVG) at baseline and at 3-, 6-, 18-month follow-up and the second patient had OCT assessment of BVS implanted in the SVG at baseline and 24-, 48-month follow-up. The second and the third patients had OCT and HD-IVUS imaging at baseline and 48-month follow-up. The last 3 patients had OCT imaging of BVS implanted in the native coronary artery at 48-month follow-up.
Results:
There were no differences in neointimal hyperplasia after BVS implantation between each time point. However, complete scaffold coverage was observed only 48 months after implantation. Out of 202 analyzed scaffold struts, there were 67 (33%) black boxes detectable at 48-month follow-up. HD-IVUS presented plaque burden up to 67% at the segment of BVS implantation at 48-months follow-up. There was a difference in neointimal hyperplasia thickness (1.27 (0.953-1.696) vs. 0.757 (0.633-0.848), p < 0.001) between a native coronary artery and BVS scaffolds at 48-month follow-up.
Conclusions:
Bioresorbable vascular scaffold implanted in SVG characterized moderate neointimal hyperplasia as excessive as compared to native coronary arteries at long-term follow-up. The complete scaffold coverage was observed only 48 months after implantation.
More Related Videos
09:43In vivo Near Infrared Fluorescence NIRF Intravascular Molecular Imaging of Inflammatory Plaque, a Multimodal Approach to Imaging of Atherosclerosis
Published on: August 4, 2011
07:13Implantation of Tissue-Engineered Vascular Graft in Mouse Carotid Artery via Cuff Technique
Published on: May 2, 2025
Related Concept Videos
08:46Implantation of Electrospun Vascular Grafts with Optimized Structure in a Rat Model
09:43In vivo Near Infrared Fluorescence (NIRF) Intravascular Molecular Imaging of Inflammatory Plaque, a Multimodal Approach to Imaging of Atherosclerosis
07:13Implantation of Tissue-Engineered Vascular Graft in Mouse Carotid Artery via Cuff Technique
11:17Surgical Technique for the Implantation of Tissue Engineered Vascular Grafts and Subsequent In Vivo Monitoring
12:39Implantation of Inferior Vena Cava Interposition Graft in Mouse Model
06:09Femoral Vascular Graft Implantation in a Swine Model to Test Small-Diameter Vascular Grafts