Precautions for using a Filter Protection Device with a Flow Reversal Method during Carotid Artery Stenting: A Case

Tomotaka Ohshima1, Shigeru Miyachi1, Naoki Matsuo2

  • 1Neuroendovascular Therapy Center, Aichi Medical University, Nagakute, Aichi, Japan.

Related Concept Videos

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis04:30

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis

A model of stent implantation in mouse carotid artery is described. Compared to other similar methods, this procedure is very rapid, simple and accessible, offering the possibility to study in a convenient way the vascular wall reaction to different drug-eluting stents and the molecular mechanisms of...
26.2K
A Model of Disturbed Flow-Induced Atherosclerosis in Mouse Carotid Artery by Partial Ligation and a Simple Method of RNA Isolation from Carotid Endothelium11:00

A Model of Disturbed Flow-Induced Atherosclerosis in Mouse Carotid Artery by Partial Ligation and a Simple Method of RNA Isolation from Carotid Endothelium

This describes a partial carotid ligation surgery, which causes disturbed flow conditions and subsequent atherosclerosis development (in two weeks) with intraplaque neo-vascularization (in four weeks) in the mouse common carotid artery. We also describe a novel method of RNA isolation from the carotid intima, providing high purity endothelial...
29.7K
Passive Filters01:27

Passive Filters

Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
959
Active Filters01:25

Active Filters

Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
1.3K
Ferric Chloride-induced Thrombosis Mouse Model on Carotid Artery and Mesentery Vessel07:26

Ferric Chloride-induced Thrombosis Mouse Model on Carotid Artery and Mesentery Vessel

The FeCl3 induced thrombosis model in mice is described herein. A method to monitor thrombus growth by intravital microscopy observation on a mesenteric vessel and by blood flow measurement in the carotid artery is...
18.6K
Air Filter Devices Including Nonwoven Meshes of Electrospun Recombinant Spider Silk Proteins09:51

Air Filter Devices Including Nonwoven Meshes of Electrospun Recombinant Spider Silk Proteins

Spider silk fibers display extraordinary mechanical properties. Engineered Araneus diadematus Fibroin 4 (eADF4) can be processed into nonwoven meshes using electrospinning. Here, the eADF4 nonwoven meshes are used to improve the performance of air filtering...
16.5K